0000000000254055

AUTHOR

T. V. Bartolotta

Trans-cranial Magnetic Resonance-guided Focused UltraSound (tcMRgFUS) system integrated with a 1.5T: an SNR study on DQA phantoms

Background: In recent years transcranial Magnetic Resonance-guided Focused Ultrasound Surgery (tcMRgFUS) treatments have been performed only using 3T units. Since following some internal analysis, planning images obtained using a 1.5T MRI’s body RF coil (as usually done with 3T systems) showed generally reasonable quality in terms of anatomy visualization and SNR but thermal images noise was above acceptable standard for treatments, a dedicated 2-channels head coil was developed (InSightec Ltd.) to ensure an adequate signal-to-noise ratio (SNR). Hence, we present the imaging protocol and the technological methods successfully used with the world-first installation of a certified tcMRgFUS sy…

research product

ADVANCEMENTS IN COMPUTER-AIDED BI-RADS US CHARACTERIZATION OF FOCAL BREAST LESIONS: CLINICAL ASSESSMENT OF A NEW SOFTWARE RELEASE OF S-DETECT

research product

Transcranial Magnetic Resonance-guided Focused Ultrasound Surgery (tcMRgFUS) at 1.5T: this is how we do it

Aims and objectives Methods and materials Results Conclusion Personal information References

research product

Liver stiffness quantification in patients with non-alcoholic steatohepatitis: comparison of shear wave elastography and transient elastography with liver biopsy correlation

Purpose: To assess the accuracy of liver stiffness quantification in patients with non-alcoholic steatohepatitis (NASH) using shear wave elastography (SWE) in comparison with transient elastography (TE). Methods and Materials: This is a prospective study performed in a single institution, including 49 patients with histological diagnosis of NASH. The stiffness of the right liver lobe was measured on the same day with two techniques: TE (FibroScan, Echosens), and SWE (RS80A ultrasound system, Samsung Medison). In the SWE evaluation, 11 patients were excluded due to more than 75% measurements fails. Receiver operating curves (ROC), areas under the ROC (AUROC) and 95% confidence intervals (CI)…

research product

BACKGROUND PARENCHYMAL ENHANCEMENT, MAMMOGRAPHIC DENSITY AND RISK OF BREAST CANCER

research product

Voxel-Based Morphomerty study in patients with amnestic Mild Cognitive Impairment and Alzheimer's Disease: population-based data from the Zabùt Aging Project

Aims and objectives Methods and materials Results Conclusion Personal information References

research product