Effect of the Time Dependent Loading of Type IV Cylinders using a Multiscale Model
International audience; The current requirements for composite cylinders are still based on an arbitrary approach derived from the behaviour of metal structures, that the designed burst pressure should be at least 2.5 times the maximum in-service pressure [1]. This could lead to an over-designed composite cylinder for which the weight saving would be less than optimum. Moreover, predicting the lifetime of composite cylinders is a challenging task due to their anisotropic characteristics. A federal research institute in Germany (BAM) has proposed a minimum load-cycle requirement that mitigates this issue by using a Monte-Carlo analysis of the burst test results [2-3]. To enrich this study, m…