0000000000256456
AUTHOR
B. Kardan
Electromagnetic Calorimeter for HADES Experiment
Electromagnetic calorimeter (ECAL) is being developed to complement dilep- ton spectrometer HADES. ECAL will enable the HADES@FAIR experiment to mea- sure data on neutral meson production in heavy ion collisions at the energy range of 2-10 AGeV on the beam of future accelerator SIS100@FAIR. We will report results of the last beam test with quasi-monoenergetic photons carried out in MAMI facility at Jo- hannes Gutenberg Universitat Mainz.
Verification of Electromagnetic Calorimeter Concept for the HADES spectrometer
The HADES spectrometer currently operating on the beam of SIS18 accelerator in GSI will be moved to a new position in the CBM cave of the future FAIR complex. Electromagnetic calorimeter (ECAL) will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeVon the beam of the new accelerator SIS100. Calorimeter will be based on 978 massive lead glass modules read out by photomultipliers and a novel front-end electronics. Secondary gamma beam with energies ranging from 81 MeV up to 1399 MeV from MAMI-C Mainz facility was used to verify selected technical solutions. Relative energy resolution was measured using modules…