0000000000264231

AUTHOR

Alexander Oberhuber

0000-0002-6322-7152

showing 3 related works from this author

A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.

2016

Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…

MaleTime FactorsDatabases FactualEndoleakComputed Tomography Angiographymedicine.medical_treatmentBlood Loss Surgical030204 cardiovascular system & hematologyEndovascular aneurysm repair030218 nuclear medicine & medical imaging0302 clinical medicineRisk FactorsGermanyMedicineHospital MortalityAged 80 and overEndovascular ProceduresGraft Occlusion VascularArteriesMiddle AgedCommon iliac arteryInternal iliac arteryAbdominal aortic aneurysmTreatment OutcomeIliac AneurysmFemaleStentsRadiologyCardiology and Cardiovascular Medicinemedicine.medical_specialtyRevascularizationProsthesis DesignPelvis03 medical and health sciencesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryHumansVascular PatencyAgedRetrospective Studiesbusiness.industryExternal iliac arteryAngiography Digital Subtractionmedicine.diseaseSurgeryBlood Vessel ProsthesisFeasibility StudiesSurgerybusinessJournal of vascular surgery
researchProduct

Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.

2018

Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, an…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignEndovascular aneurysm repairRisk Assessment03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsRisk FactorsmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineMyocardial infarctionAdverse effectStrokeAgedAged 80 and overbusiness.industryPatient SelectionEndovascular ProceduresMiddle Agedmedicine.diseaseThrombosisAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisProsthesis FailureTreatment OutcomeRespiratory failureSurgeryFemaleStentsCardiology and Cardiovascular MedicineParaplegiabusinessAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Editor's Choice – Occurrence and Classification of Proximal Type I Endoleaks After EndoVascular Aneurysm Sealing Using the Nellix™ Device

2017

Objective/Background Proximal type I endoleaks are associated with abdominal aortic aneurysm (AAA) growth and rupture and necessitate repair. The Nellix™ EndoVascular Aneurysm Sealing (EVAS) system is a unique approach to AAA repair, where the appearance and treatment of endoleaks is also different. This study aimed to analyse and categorise proximal endoleaks in an EVAS treated cohort. Methods All patients, treated from February 2013 to December 2015, in 15 experienced EVAS centres, presenting with proximal endoleak were included. Computed tomography scans were analysed by a core laboratory. A consensus meeting was organised to discuss and qualify each case for selection, technical aspects…

Malemedicine.medical_specialtyEndoleakmedicine.medical_treatmentTechnical successEarly detectionComputed tomography030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineAneurysmRisk FactorsHumansMedicineAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryIncidenceIncidence (epidemiology)Endovascular ProceduresStentMiddle Agedmedicine.diseaseAbdominal aortic aneurysmSurgeryTreatment OutcomeFemaleSurgeryCore laboratoryCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalEuropean Journal of Vascular and Endovascular Surgery
researchProduct