0000000000269952

AUTHOR

Antonio Rodríguez-galietero

Goldmann Applanation Tonometry Using Sterile Disposable Silicone Tonometer Shields

Abstract Purpose: Placement of a sterile single-use cover over the tonometer tip may be a convenient and safe alternative method to repeated chemical disinfection. This study was undertaken to evaluate the accuracy and performance of Goldmann applanation tonometry using a sterile disposable silicone tonometer shield over the biprism tip. Methods: The same investigator measured intraocular pressure in 120 eyes with and without the shield. The eyes were tested randomly first with either the uncovered or the covered tonometer to control for the possible effects of repeated tonometry influencing measurement differences. Readings were recorded independently in a masked fashion. Results: The intr…

research product

Femtosecond laser versus mechanical keratome LASIK for myopia.

To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…

research product

Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome

ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…

research product

Role of oxygen and nitrogen species in experimental uveitis: anti-inflammatory activity of the synthetic antioxidant ebselen.

This study was aimed at examining the role of oxygen and nitrogen reactive species in a model of experimental uveitis upon intravitreal injection of bacterial endotoxin to albino New Zealand rabbits. The inflammatory response was evaluated in terms of: (i) the integrity of the blood aqueous barrier (protein and cell content in samples of aqueous humor), (ii) histopathological changes of the eyes, (iii) clinical evaluation (with a score index based on clinical symptoms), and (iv) the concentration of malondialdehyde (MDA), in aqueous humor, as a marker of oxidative stress. Betamethasone was used as reference treatment, superoxide dismutase as quencher of superoxide anion, L-N(G)-nitro-L-argi…

research product