0000000000274080

AUTHOR

Dominic Upton

The effectiveness of local child weight management programmes: an audit study

Background Many different child weight management programmes exist, with varying degrees of evaluation to provide evidence of their success. The purpose of this research was to use a standardized approach to audit the effectiveness of weight management intervention programmes in the West Midlands region of the UK, specifically to assess the benefits to participating children in terms of health improvement and behaviour change. Methods An audit of seven family-based intervention programmes currently in place in the West Midlands. Programmes were audited against the Standard Evaluation Framework. Results The programmes provided a partial data set relating to a change in weight from the baseli…

research product

The impact of school-day variation in weight and height on National Child Measurement Programme body mass index-determined weight category in Year 6 children

Background In England, the National Child Measurement Programme (NCMP) annually measures the weight and height of Year 6 school children (age 10–11 years). While measurement protocols are defined, the time of measurement within the school day is not. This study examined the impact of school-day variation in weight and height on NCMP body mass index (BMI)-determined weight category in Year 6 children. Methods Standing height and weight were measured in morning and afternoon sessions in 74 children, boys (n= 34; height: 141.16 ± 7.45 cm; weight: 36.48 ± 9.46 kg, BMI: 18.19 ± 3.98 kg/m2) and girls (n= 40; height: 144.58 ± 7.66 cm; weight: 42.25 ± 11.29 kg; BMI: 19.97 ± 3.98 kg/m2) aged 11 ± 0.…

research product

Intra‐ and inter‐instrument reliability of the Actiwatch 4 accelerometer in a mechanical laboratory setting.

Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting This study aimed to quantify the intra-and inter-instrument reliability of the Actiwatch 4 accelerometer (AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA condition) and 200 deg/sec representing vigorous intensity (VPA condition), with a repeat trial conducted. Reliability was assessed using coefficient of variation (CV), absolute percent error (APE), and intraclass correlation coefficients (ICC). Mean AW4 activity counts displayed acceptable rel…

research product