Phantom development for daily checks in electron intraoperative radiotherapy with a mobile linac.

2020

Abstract Purpose IORT with mobile linear accelerators is a well-established modality where the dose rate and, therefore, the dose per pulse are very high. The constancy of the dosimetric parameters of the accelerator has to be checked daily. The aim of this work is to develop a phantom with embedded detectors to improve both accuracy and efficiency in the daily test of an IORT linac at the surgery room. Methods The developed phantom is manufactured with transparent polymethyl methacrylate (PMMA), allocating 6 parallel-plate chambers: a central one to evaluate the on-axis beam output, another on-axis one placed at a fixed depth under the previous one to evaluate the energy constancy and four…

Intraoperative radiotherapyMaterials scienceFlatness (systems theory)BiophysicsGeneral Physics and AstronomyElectronsLinear particle acceleratorImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsDosimetryIonizationDosimetryRadiology Nuclear Medicine and imagingRadiometrybusiness.industryPhantoms ImagingDetectorRadiotherapy DosageGeneral MedicineQuality assurance030220 oncology & carcinogenesisParticle AcceleratorsbusinessQuality assuranceBeam (structure)Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
researchProduct

Novel simple templates for reproducible positioning of skin applicators in brachytherapy.

2016

Purpose : Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the po…

0106 biological sciencesEngineering drawingmedicine.medical_specialtyMedical staffelectronic brachytherapymedicine.medical_treatmentTreatment outcomeBrachytherapybrachytherapylcsh:Medicine01 natural sciences03 medical and health sciences0302 clinical medicineMargin (machine learning)medicineRadiology Nuclear Medicine and imagingMedical physicsReview Paperskin cancerbusiness.industrylcsh:RtemplateThin sheetClinical Practiceskin applicatorsTemplateOncology030220 oncology & carcinogenesisbusiness010606 plant biology & botanyJournal of contemporary brachytherapy
researchProduct

Assessing the Relationship Between Dose-Volume Histogram Parameters and Late Rectal Toxicity in HDR Brachytherapy for Prostate Cancer

2017

Oncologymedicine.medical_specialtyDose-volume histogrambusiness.industrymedicine.medical_treatmentBrachytherapyRectal toxicitymedicine.diseaseProstate cancerOncologyInternal medicinemedicineRadiology Nuclear Medicine and imagingRadiologybusinessBrachytherapy
researchProduct

Improving bleeding detector features for electron intraoperative radiotherapy

2019

Abstract Purpose The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been develope…

Materials scienceRadiotherapybusiness.industryOrientation (computer vision)Capacitive sensingDetectorBiophysicsGeneral Physics and AstronomyElectronsHemorrhageGeneral MedicineElectronLinear particle accelerator030218 nuclear medicine & medical imagingIntraoperative Period03 medical and health sciences0302 clinical medicineOptics030220 oncology & carcinogenesisRadiology Nuclear Medicine and imagingParticle AcceleratorsbusinessIntraoperative radiotherapyQuality assuranceSignal conditioningPhysica Medica
researchProduct

Detector for monitoring potential bleeding during electron intraoperative radiotherapy

2018

Purpose: The aim of this work is to develop a bleeding detector integrated into the acrylic circular applicators for specific mobile linacs. Thus, a bleeding detector has been developed based on a capacitive sensor to be used with plastic applicators, as in the case of LIAC HWL from Sordina IORT Technologies SpA. According to the clinical impact, we have selected 0.5 cm as the minimum depth of fluid that should be detected. Methods: An experiment was developed using water-simulating blood. Two setups were considered: non-beveled applicators with 7 cm and 10 cm diameter. Measurements were done for applicators 0 degrees and 45 degrees tilted, both with respect to the horizontal surface, in or…

Intraoperative radiotherapyMaterials scienceCapacitive sensingBiophysicsPhase (waves)General Physics and AstronomyElectronsHemorrhageRadiation030218 nuclear medicine & medical imagingIntraoperative Period03 medical and health sciences0302 clinical medicineOpticsRadiology Nuclear Medicine and imagingIrradiationRadiation InjuriesRadiotherapybusiness.industryBleedingContinuous monitoringDetectorLinearityGeneral MedicineBevel030220 oncology & carcinogenesisCapacitive sensorParticle AcceleratorsbusinessPhysica Medica
researchProduct

High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity

2017

PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…

MaleOrgans at RiskDose-volume histogramTime Factorsmedicine.medical_treatmentBrachytherapyBrachytherapyRectumLate rectal toxicity030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancerOrgan at risk0302 clinical medicinemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesExternal beam radiotherapyRadiation InjuriesAgedAged 80 and overProstate cancerbusiness.industryRadiotherapy Planning Computer-AssistedBiologically equivalent doseRectumProstatic NeoplasmsCommon Terminology Criteria for Adverse EventsMiddle Agedmedicine.diseaseCombined Modality TherapyHigh-Dose Rate BrachytherapyHigh-dose-rate brachytherapy boostRadiation therapyDose-volume histogram parametermedicine.anatomical_structureOncology030220 oncology & carcinogenesisRegression AnalysisDose Fractionation RadiationNuclear medicinebusinessFollow-Up Studies
researchProduct