Novel simple templates for reproducible positioning of skin applicators in brachytherapy.

2016

Purpose : Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the po…

0106 biological sciencesEngineering drawingmedicine.medical_specialtyMedical staffelectronic brachytherapymedicine.medical_treatmentTreatment outcomeBrachytherapybrachytherapylcsh:Medicine01 natural sciences03 medical and health sciences0302 clinical medicineMargin (machine learning)medicineRadiology Nuclear Medicine and imagingMedical physicsReview Paperskin cancerbusiness.industrylcsh:RtemplateThin sheetClinical Practiceskin applicatorsTemplateOncology030220 oncology & carcinogenesisbusiness010606 plant biology & botanyJournal of contemporary brachytherapy
researchProduct

SU-E-J-64: Evaluation of a Commercial EPID-Based in Vivo Dosimetric System in the Presence of Lung Tissue Heterogeneity

2014

Purpose: To study the performance of Dosimetry Check (DC), an EPID-based dosimetry software, which allows performing transit dosimetry, in low density medium, by comparing calculations in-phantom, and analysing results for 15 lung patients. Methods: DC software (v.3.8, pencil beam-based algorithm) has been tested, for plans (Eclipse v.10.0 TPS) delivered in two Varian Clinac iX equipped with aS1000 EPIDs.In the CIRS lung phantom, comparisons between DC and Eclipse (Acuros) were performed for several plans: (1) four field box; (2) square field delivered in arc mode; (3) RapidArc lung patient plan medially centred; (4) RapidArc lung patient plan centred in one lung. Reference points analysed:…

Case (situation)business.industryLow densityDosimetryMedicinePencil beam algorithmGeneral MedicineLung tissueIn vivo dosimetryNuclear medicinebusinessImaging phantomMedical Physics
researchProduct

Response to “Comment on ‘Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brac…

2016

Physicsbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyThermal ionizationGeneral Medicine030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicineLow energy030220 oncology & carcinogenesisIonizationCalibrationmedicineMeasurement uncertaintyDosimetryNuclear medicinebusinessMedical Physics
researchProduct

Dosimetric Characteristics of a New Unit for Electronic Skin Brachytherapy

2014

medicine.medical_specialtyOncologybusiness.industrymedicine.medical_treatmentBrachytherapyElectronic skinMedicineRadiology Nuclear Medicine and imagingMedical physicsbusinessUnit (housing)Brachytherapy
researchProduct

Dosimetric characteristics of a new unit for electronic skin brachytherapy

2013

PURPOSE: Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachytherapy with the reduced shielding requirements and targeted energy of low energy X-rays. Recently, the Esteya(®) Electronic Brachytherapy System (Esteya EBS, Elekta AB-Nucletron, Stockholm, Sweden) has been developed specifically for HDR brachytherapy treatment of surface lesions. The system provides rad…

Original Paperelectronic brachytherapybusiness.industrymedicine.medical_treatmentTreatment durationSuperficial radiotherapyBrachytherapyElectronic skinsuperficial radiotherapyRadiation therapyLow energyOncologynonmelanoma skin-cancermedicineskin brachytherapyRadiology Nuclear Medicine and imagingNuclear medicinebusinessDose rateDepth doseJournal of Contemporary Brachytherapy
researchProduct

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

2015

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit …

Physicsbusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineCollimated lightKermaOpticsAbsorbed doseIonizationIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

2014

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm3 sized ion chambers covering 11×11 cm2, which spacing is 2.5 mm in the central 5.5…

PhysicsTime delay and integrationbiologybusiness.industryFlatness (systems theory)General MedicineIntensity-modulated radiation therapybiology.organism_classificationOpticsIonization chamberStandard protocolPatient dosebusinessNuclear medicineValenciaMedical Physics
researchProduct