0000000000302518

AUTHOR

E. Martin

Calibration of high voltages at the ppm level by the difference of $$^{83{\mathrm{m}}}$$ 83m Kr conversion electron lines at the KATRIN experiment

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at − 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $$^{83{\mathrm{m}}}$$ 83m Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN’s commissioning measurements …

research product

Search for Production of Invisible Final States in Single-Photon Decays of Υ(1S)

We search for single-photon decays of the Upsilon(1S) resonance, Upsilon->gamma+invisible, where the invisible state is either a particle of definite mass, such as a light Higgs boson A0, or a pair of dark matter particles, chi chi-bar. Both A0 and chi are assumed to have zero spin. We tag Upsilon(1S) decays with a dipion transition Upsilon(2S)->pi+pi-Upsilon(1S) and look for events with a single energetic photon and significant missing energy. We find no evidence for such processes in the mass range m_A0<=9.2 GeV and m_chi<=4.5 GeV in the sample of 98e6 Upsilon(2S) decays collected with the BaBar detector and set stringent limits on new physics models that contain light dark ma…

research product

VISTA Milky Way Public Survey

We propose a public IR variability survey, named \Vista Variables in the Vía Láctea" (V V V ), of the Milky Way bulge and an adjacent section of the mid-plane where star formation activity is high. This would take 1920 hours, covering ~ 109 point sources within an area of 520 sq deg, including 33 known globular clusters and ~ 350 open clusters. The final products will be a deep IR atlas in 5 passbands and a catalogue of ~ 106 variable point sources. These will produce a 3-D map of the surveyed region (unlike single-epoch surveys that only give 2-D maps) using well-understood primary distance indicators such as RR Lyrae stars. It will yield important information on the ages of the population…

research product

Study of the exclusive initial-state-radiation production of the D¯¯¯D system

A study of exclusive production of the $D \bar D$ system through initial-state r adiation is performed in a search for charmonium states, where $D=D^0$ or $D^+$. The $D^0$ mesons are reconstructed in the $D^0 \to K^- \pi^+$, $D^0 \to K^- \pi^+ \pi^0$, and $D^0 \to K^- \pi^+ \pi^+ \pi^-$ decay modes. The $D^+$ is reconstructed through the $D^+ \to K^- \pi^+ \pi^+$ decay mode. The analysis makes use of an integrated luminosity of 288.5 fb$^{-1}$ collected by the BaBar experiment. The $D \bar D$ mass spectrum shows a clear $\psi(3770)$ signal. Further structures appear in the 3.9 and 4.1 GeV/$c^2$ regions. No evidence is found for Y(4260) decays to $D \bar D$, implying an up per limit $\frac{\…

research product

SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study

Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…

research product

Early outcomes and complications following cardiac surgery in patients testing positive for coronavirus disease 2019: An international cohort study

The outbreak of severe acute respiratory syndromecoronavirus-2, the cause of coronavirus disease 2019 (COVID-19) in December 2019 represented a global emergency accounting for more than 2.5 million deaths worldwide.1 It has had an unprecedented influence on cardiac surgery internationally, resulting in cautious delivery of surgery and restructuring of services.2 Understanding the influence of COVID-19 on patients after cardiac surgery is based on assumptions from other surgical specialties and single-center studies. The COVIDSurg Collaborative conducted a multicenter cohort study, including 1128 patients, across 235 hospitals, from 24 countries demonstrating perioperative COVID-19 infection…

research product

Gamma-induced background in the KATRIN main spectrometer

The KATRIN experiment aims to measure the effective electron antineutrino mass $$m_{\overline{\nu }_e}$$ mν¯e with a sensitivity of $${0.2}\,{\hbox {eV}/\hbox {c}^2}$$ 0.2eV/c2 using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the e…

research product

Machine learning risk prediction of mortality for patients undergoing surgery with perioperative SARS-CoV-2: the COVIDSurg mortality score

The British journal of surgery 108(11), 1274-1292 (2021). doi:10.1093/bjs/znab183

research product

Nonradical oxidants of the phagocyte type induce the activation of plasmatic single chain- urokinase

Single chain- urokinase (scu-PA) is the proenzyme of the plasminogen activator urokinase (tcu-PA). In human blood scu-PA is of great stability. Activated phagocytes generate large amounts of single chain- urokinase and of reactive oxidants (chloramines and HOCl). Since these cells participate in physiologic fibrinolysis, we were interested in the interaction between plasmatic scu-PA and chloramines. The oxidants dose dependently induce the activation of plasmatic scu-PA. Optimal activation of scu-PA occurs at about 3-5 mmol/l of chloramine-T. The findings suggest a control mechanism of scu-PA stability/activity by oxidatively modifiable plasma proteins, such as alpha-2-antiplasmin. The oxid…

research product

Tumeurs localisées du sein triple négatives en 2016 : définitions et prise en charge

Triple-negative breast cancer (TN), as defined by the triple negativity in immunohistochemistry: the absence of estrogen receptor, progesterone receptor and the absence of overexpression or amplification of HER2, corresponds to 15 % of invasive breast cancers. This is a very heterogeneous group of tumors both at the genomic and transcriptomic level and at morphological, clinical and prognostic level. Although there are some good prognosis forms, the majority of TN tumors is characterized by a poor prognosis with a greater frequency of visceral metastases and a maximum risk of relapse in the first two years after diagnosis. Systemic adjuvant treatment with chemotherapy is almost always indic…

research product

OMC: An Optical Monitoring Camera for INTEGRAL - Instrument description and performance

The Optical Monitoring Camera (OMC) will observe the optical emission from the prime targets of the gammaray instruments onboard the ESA mission INTEGRAL, with the support of the JEM-X monitor in the X-ray domain. This capability will provide invaluable diagnostic information on the nature and the physics of the sources over a broad wavelength range. Its main scientific objectives are: ( 1) to monitor the optical emission from the sources observed by the gamma- and X-ray instruments, measuring the time and intensity structure of the optical emission for comparison with variability at high energies, and ( 2) to provide the brightness and position of the optical counterpart of any gamma- or X…

research product