0000000000329551

AUTHOR

Monique Bernard

Cardiovascular magnetic resonance-derived aortic compliance, distensibility and pulse wave velocity at rest and during a supine bicycle exercise in young adults: A pilot study.

Background Purpose: Risk of aortic rupture is evaluated based on the vessel diameter; this parameter is probably insufficient. In vivo evaluation of biomechanical property of the aortic tissue might be of interest to discriminate between normal and altered aortic tissue (A Lalande et al, JMRI 2008). The purpose of this study was to describe a technique to measure regional aortic compliance (AC), aortic distensibility (AD) and aortic stiffness with 1.5 T MRI in young individuals under resting conditions and during supine bicycle exercise.

research product

Exercise stress CMR reveals reduced aortic distensibility and impaired right-ventricular adaptation to exercise in patients with repaired tetralogy of Fallot

International audience; The aim of our study was to evaluate the feasibility of exercise cardiac magnetic resonance (CMR) in patients with repaired tetralogy of Fallot (RTOF) and to assess right and left ventricular adaptation and aortic wall response to exercise in comparison with volunteers.Methods11 RTOF and 11 volunteers underwent prospective CMR at rest and during exercise. A supine bicycle ergometer was employed to reach twice the resting heart rate during continuous exercise, blood pressure and heart rate were recorded. Bi-ventricular parameters and aortic stiffness were assessed using accelerated cine sequences and flow-encoding CMR. A t-test was used to compare values between group…

research product

Aortic Function's Adaptation in Response to Exercise-Induced Stress Assessing by 1.5T MRI : A Pilot Study in Healthy Volunteers

AIM:Evaluation of the aortic "elastic reserve" might be a relevant marker to assess the risk of aortic event. Our aim was to compare regional aortic elasticity at rest and during supine bicycle exercise at 1.5 T MRI in healthy individuals. METHODS:Fifteen volunteers (8 men), with a mean age of 29 (23-41) years, completed the entire protocol. Images were acquired immediately following maximal exercise. Retrospective cine sequences were acquired to assess compliance, distensibility, maximum rates of systolic distension and diastolic recoil at four different locations: ascending aorta, proximal descending aorta, distal descending aorta and aorta above the coeliac trunk level. Segmental aortic …

research product

Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition)

Seuls les 100 premiers auteurs dont les auteurs INRA ont été entrés dans la notice. La liste complète des auteurs et de leurs affiliations est accessible sur la publication.; International audience; In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues…

research product

NCprocessing: a software to determine non-compacted and compacted masses from MRI

International audience

research product

Semiautomatic detection of myocardial contours in order to investigate normal values of the left ventricular trabeculated mass using MRI

Purpose To propose, assess, and validate a semiautomatic method allowing rapid and reproducible measurement of trabeculated and compacted left ventricular (LV) masses from cardiac magnetic resonance imaging (MRI). Materials and Methods We developed a method to automatically detect noncompacted, endocardial, and epicardial contours. Papillary muscles were segmented using semiautomatic thresholding and were included in the compacted mass. Blood was removed from trabeculae using the same threshold tool. Trabeculated, compacted masses and ratio of noncompacted to compacted (NC:C) masses were computed. Preclinical validation was performed on four transgenic mice with hypertrabeculation of the LV…

research product

Erratum

Author(s): Klionsky, DJ; Abdelmohsen, K; Abe, A; Abedin, MJ; Abeliovich, H; Arozena, AA; Adachi, H; Adams, CM; Adams, PD; Adeli, K; Adhihetty, PJ; Adler, SG; Agam, G; Agarwal, R; Aghi, MK; Agnello, M; Agostinis, P; Aguilar, PV; Aguirre-Ghiso, J; Airoldi, EM; Ait-Si-Ali, S; Akematsu, T; Akporiaye, ET; Al-Rubeai, M; Albaiceta, GM; Albanese, C; Albani, D; Albert, ML; Aldudo, J; Algul, H; Alirezaei, M; Alloza, I; Almasan, A; Almonte-Beceril, M; Alnemri, ES; Alonso, C; Altan-Bonnet, N; Altieri, DC; Alvarez, S; Alvarez-Erviti, L; Alves, S; Amadoro, G; Amano, A; Amantini, C; Ambrosio, S; Amelio, I; Amer, AO; Amessou, M; Amon, A; An, Z; Anania, FA; Andersen, SU; Andley, UP; Andreadi, CK; Andrieu-Ab…

research product