0000000000340288
AUTHOR
A Pirrotta
Performance and optimal design of Tuned Mass Damper Inerter for base isolated systems
In this paper, the use of a Tuned Mass Damper Inerter to mitigate the seismic response of a base-isolated structure is studied and compared to other passive control devices. The control performance of four different types of hybrid passive control strategies aiming to reduce base displacements of isolated buildings is investigated. Specifically, the Tuned Mass Damper (TMD), the Tuned Liquid Column Damper (TLCD), and finally, the Tuned Mass Damper Inerter, each one associated to a Base Isolated structure (BI system) have been considered. This study has been carried out using as optimal design parameters of the TMDI those estimated by a proposed direct optimization procedure, considering a wh…
Non-stationary dynamic analysis of random structures via virtual distortion method
Efficient estimation of tuned liquid column damper inerter (TLCDI) parameters for seismic control of base‐isolated structures
This paper presents an enhanced base-isolation (BI) system equipped with a novel passive control device composed of a tuned liquid damper and an inerter (TLCDI). With the aim of reducing the seismic response of BI systems, this contribution focuses on the design of the TLCDI providing analytical solutions for the optimal TLCDI parameters, easily implementable in the design phase. The effectiveness of the proposed approach in terms of seismic response reduction and computational gain is validated by comparison with classical numerical optimization techniques. The control performance of two different base-isolated TLCDI-controlled structures is assessed by employing real-ground motion records…