0000000000353579

AUTHOR

Thomas J. Vogl

showing 6 related works from this author

CT-guided nephrostomy–An expedient tool for complex clinical scenarios

2018

Abstract Introduction & objectives Percutaneous nephrostomy [ 1 ] has emerged as a pivotal approach in the therapeutic management of the obstructed urinary tract. A consecutive incorporation of ultrasonic and radiographic guidance, the approach experienced an almost ubiquitious distribution while most centers currently applying either one or both of these tools jointly. However, success of ultrasound-guidance is limited in obese patients and non-dilated uropathy. In turn, fluoroscopy usually requires an opacification of the urinary collecting system by intravenous or antegrade contrast media injection, which might be harmful for already impaired renal function, raise intrapelvic pressure an…

MaleUrologic Diseasesmedicine.medical_specialtySupine positionUrinary systemmedicine.medical_treatmentKidneyRadiography Interventional030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineUrethral DiseasesmedicineHumansRadiology Nuclear Medicine and imagingObesityRenal InsufficiencyObstructive uropathyUltrasonography InterventionalAgedNephrostomy PercutaneousRetrospective Studiesbusiness.industryMortality rateGeneral MedicineOverweightmedicine.diseaseSurgeryProne positionSurgery Computer-AssistedPercutaneous nephrostomyFluoroscopy030220 oncology & carcinogenesisFeasibility StudiesFemaleMedian bodyTomography X-Ray ComputedbusinessComplicationAnesthesia LocalDilatation PathologicEuropean Journal of Radiology
researchProduct

Biological responses to individualized small titanium implants for the treatment of focal full-thickness knee cartilage defects in a sheep model.

2019

Abstract Background The present study aimed to evaluate the functional, radiological and histological outcome of a customized focal implant for the treatment of focal full-thickness cartilage defects in sheep. Methods The study used magnetic resonance imaging data as the basis for construction of the titanium implant using a three-dimensional printing technique. This was then placed on the medial condyle of the knee joint in eight sheep and left in place in vivo over a period of six months. Following euthanasia, the local biological response was analyzed using micro-computed tomography, light microscopy and histological evaluation (International Cartilage Repair Society (ICRS) score). The v…

Cartilage ArticularKnee Jointmedicine.medical_treatmentPopulationKnee JointProsthesisCondyleOsseointegrationProsthesis Implantation03 medical and health sciences0302 clinical medicineOsseointegrationProsthesis FittingmedicineAnimalsOrthopedics and Sports Medicineeducation030203 arthritis & rheumatologyOrthodonticsTitanium030222 orthopedicseducation.field_of_studySheepmedicine.diagnostic_testbusiness.industryCartilageMagnetic resonance imagingX-Ray MicrotomographyRadiographymedicine.anatomical_structureModels AnimalImplantbusinessKnee ProsthesisCartilage DiseasesThe Knee
researchProduct

Ruptured angiomyolipoma of the kidney: a rare differential diagnosis of flank pain.

2017

Angiomyolipomas (AMLs) of the kidney are typically benign and rare, with an incidence of 2% of all renal masses [1]. They are associated with tuberous sclerosis in about 20% of cases. If ruptured, ...

AdultMalemedicine.medical_specialtyAngiomyolipomaFlank painUrologyAngiomyolipoma030232 urology & nephrologyUreteral stoneFlank PainDiagnosis Differential03 medical and health sciencesTuberous sclerosis0302 clinical medicinemedicineHumansKidneyRupture Spontaneousbusiness.industryIncidence (epidemiology)food and beveragesmedicine.diseaseKidney NeoplasmsSurgeryTomography x ray computedmedicine.anatomical_structureNephrology030220 oncology & carcinogenesisRadiologyDifferential diagnosisbusinessTomography X-Ray ComputedScandinavian journal of urology
researchProduct

Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions : results of a mu…

2008

The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three bli…

Gadobutrol; Gadopentate dimeglumine; Renal lesions; MRI; Diagnostic differentiation; NoninferiorityGadolinium DTPAMalemedicine.medical_specialtyContrast MediaRenal lesionsSensitivity and SpecificityGadobutrollaw.inventionGadobutrolPrecontrastRandomized controlled trialmagnetic resonance contrast medialawmedicineOrganometallic CompoundsHumansRadiology Nuclear Medicine and imagingSingle-Blind Methodddc:610Neuroradiologymedicine.diagnostic_testbusiness.industryDiagnostic differentiationUltrasoundReproducibility of ResultsMagnetic resonance imagingInterventional radiologyGeneral MedicineNoninferiorityMiddle AgedImage EnhancementMagnetic Resonance ImagingKidney NeoplasmsClinical trialEuropeRadiology Nuclear Medicine and imagingFemaleGadopentate dimeglumineRadiologybusinessNuclear medicinemedicine.drugMRI
researchProduct

Facilitating cartilage volume measurement using MRI.

2010

To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses.Ten knees were scanned with a 1.5T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5mm, 3.0mm and 5.0mm slices using the Argus software application. Accuracy and time effectiveness served as control parameters.Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6+/-127.7s and 379.1+/-117.6s to 214.9+/-109.9s and 213.9+/-102.2s to 122.1+/-60.1s and 126.8+/-56.2s and for the medial tibial platea…

AdultCartilage ArticularMaleKnee JointLateral tibial plateauArticular cartilageYoung AdultVolume measurementImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imagingControl parametersObserver VariationTibiabusiness.industryCartilageGeneral MedicineAnatomyMagnetic Resonance Imagingmedicine.anatomical_structureFemalebusinessVolume (compression)Biomedical engineeringGradient echoEuropean journal of radiology
researchProduct

Quadruple-Phase MDCT of the Liver in Patients with Suspected Hepatocellular Carcinoma: Effect of Contrast Material Flow Rate

2006

The purposes of this study were to evaluate the effect of contrast material flow rate (3 mL/sec vs 5 mL/sec) on the detection and visualization of hepatocellular carcinoma (HCC) with MDCT and the safety profile of iodixanol at different injection rates.In a prospective, randomized multicenter trial, 97 patients (83 men and 14 women, with a mean age of 64 years) suspected of having HCC underwent quadruple-phase (double arterial, portal venous, delayed phase) 4-16-MDCT. Patients were randomized to receive iodixanol, 320 mg I/mL (1.5 mL/kg body weight), at a flow rate of 3 mL/sec (48 patients) or 5 mL/sec (49 patients). Qualitative (lesion detection, image quality) and quantitative (liver and …

Malecontrast media; ct; liver disease; mdctCarcinoma Hepatocellularmedia_common.quotation_subjectcontrast mediaLiver diseaseSettore MED/36 - Diagnostica per Immagini e RadioterapiamdctTriiodobenzoic AcidsMulticenter trialCarcinomaHumansMedicineContrast (vision)Radiology Nuclear Medicine and imagingIn patientProspective StudiesProspective cohort studymedia_commonbusiness.industryLiver NeoplasmsGeneral MedicineMiddle Agedmedicine.diseaseIodixanolHepatocellular carcinomaFemaleTomography X-Ray Computedliver diseasebusinessNuclear medicinectmedicine.drugAmerican Journal of Roentgenology
researchProduct