0000000000367145

AUTHOR

Claudia Torino

showing 12 related works from this author

PANI-Based Wearable Electrochemical Sensor for pH Sweat Monitoring

2021

Nowadays, we are assisting in the exceptional growth in research relating to the development of wearable devices for sweat analysis. Sweat is a biofluid that contains useful health information and allows a non-invasive, continuous and comfortable collection. For this reason, it is an excellent biofluid for the detection of different analytes. In this work, electrochemical sensors based on polyaniline thin films deposited on the flexible substrate polyethylene terephthalate coated with indium tin oxide were studied. Polyaniline thin films were abstained by the potentiostatic deposition technique, applying a potential of +2 V vs. SCE for 90 s. To improve the sensor performance, the electronic…

Materials scienceelectrochemical sensor02 engineering and technologySubstrate (electronics)QD415-436wearable sensor010402 general chemistry01 natural sciencespH meterBiochemistryreduced graphene oxidepolyanilineAnalytical ChemistryContact anglechemistry.chemical_compoundPolyanilineSettore ING-IND/17 - Impianti Industriali MeccanicipH sensorPhysical and Theoretical ChemistryThin filmSettore ING-IND/34 - Bioingegneria Industriale021001 nanoscience & nanotechnology0104 chemical sciencesElectrochemical gas sensorIndium tin oxidesweatSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringchemistryElectrode0210 nano-technologyChemosensors
researchProduct

Inflammation is an amplifier of lung congestion by high lv filling pressure in hemodialysis patients: a longitudinal study

2019

Introduction Since infammation alters vascular permeability, including vascular permeability in the lung, we hypothesized that it can be an amplifer of lung congestion in a category of patients at high risk for pulmonary oedema like end stage kidney disease (ESKD) patients. Objective and methods We investigated the efect modifcation by systemic infammation (serum CRP) on the relationship between a surrogate of the flling pressure of the LV [left atrial volume indexed to the body surface area (LAVI)] and lung water in a series of 220 ESKD patients. Lung water was quantifed by the number of ultrasound B lines (US-B) on lung US. Six-hundred and three recordings were performed during a 2-year f…

Nephrologymedicine.medical_specialtymedicine.medical_treatment030232 urology & nephrologyInflammationVascular permeabilityInfammation030204 cardiovascular system & hematologySystemic inflammation03 medical and health sciences0302 clinical medicineRenal DialysisPulmonary edemaInternal medicinemedicineHumansLongitudinal StudiesLung congestionESRDLungInflammationBody surface areaLungbusiness.industryCardiovascular riskPulmonary edemamedicine.diseasemedicine.anatomical_structureNephrologyHemodialysisCardiologyHemodialysismedicine.symptombusinessJournal of Nephrology
researchProduct

A randomized multicenter trial on a lung ultrasound-guided treatment strategy in patients on chronic hemodialysis with high cardiovascular risk

2021

Lung congestion is a risk factor for all-cause and cardiovascular mortality in patients on chronic hemodialysis, and its estimation by ultrasound may be useful to guide ultrafiltration and drug therapy in this population. In an international, multi-center randomized controlled trial (NCT02310061) we investigated whether a lung ultrasound-guided treatment strategy improved a composite end point (all-cause death, non-fatal myocardial infarction, decompensated heart failure) vs usual care in patients receiving chronic hemodialysis with high cardiovascular risk. Patient-Reported Outcomes (Depression and the Standard Form 36 Quality of Life Questionnaire, SF36) were assessed as secondary outcome…

cardiovascular riskmedicine.medical_specialtymedicine.medical_treatmentPopulationlung congestionlaw.inventionKidney FailureRandomized controlled trialRenal DialysisRisk FactorslawMulticenter trialInternal medicineHumansMedicineChronicRisk factorESRDeducationLungUltrasonography InterventionalDialysisUltrasonographylung ultrasoundeducation.field_of_studyInterventionalbusiness.industryHazard ratiochronic kidney failuremedicine.diseaseESRD; cardiovascular risk; chronic kidney failure; heart failure hemodialysis; lung congestion; lung ultrasoundHeart Disease Risk FactorsCardiovascular DiseasesNephrologyHeart failureQuality of LifeKidney Failure ChronicHemodialysisheart failure hemodialysisbusinessKidney international
researchProduct

Cellular and Molecular Signatures of Oxidative Stress in Bronchial Epithelial Cell Models Injured by Cigarette Smoke Extract

2022

Exposure of the airways epithelium to environmental insults, including cigarette smoke, results in increased oxidative stress due to unbalance between oxidants and antioxidants in favor of oxidants. Oxidative stress is a feature of inflammation and promotes the progression of chronic lung diseases, including Chronic Obstructive Pulmonary Disease (COPD). Increased oxidative stress leads to exhaustion of antioxidant defenses, alterations in autophagy/mitophagy and cell survival regulatory mechanisms, thus promoting cell senescence. All these events are amplified by the increase of inflammation driven by oxidative stress. Several models of bronchial epithelial cells are used to study the molec…

Inflammationnatural and synthetic antioxidantsQH301-705.5cigarette smokeOrganic ChemistryBronchiEpithelial CellsGeneral MedicineCatalysisCigarette SmokingComputer Science ApplicationsInorganic ChemistryChemistryOxidative StressSettore ING-IND/23 - Chimica Fisica ApplicataSettore ING-IND/17 - Impianti Industriali MeccaniciAnimalsHumansElectrochemical sensors Bronchial epithelial cells Cigarette smoke Natural and synthetic antioxidants Oxidative stressBiology (General)Physical and Theoretical ChemistryQD1-999Molecular Biologybronchial epithelial cellsSpectroscopy
researchProduct

Silver based sensors from CD for chloride ions detection

2021

This preliminary work shows a new and innovative way to produce silver based electrodes from compact discs and its application towards the detection of chloride ions. A complete sensor was obtained from the compact discs with working, reference and counter electrode made of silver. Chloride ions were detected by exploiting the high affinity of silver with this anion to produce silver chloride. This electrochemical oxidation of silver can be monitored by using an electrochemical technique such as linear scan voltammetry. Indeed, during linear scan voltammetry the oxidation of silver to silver chloride lead to a peak current that increases linearly with chloride concentration. Using this tech…

Detection limitAuxiliary electrodevoltammetryMaterials scienceInorganic chemistrycircular economyelectrochemical sensorElectrochemistryChloride ions electrochemical sensor voltammetry circular economyChlorideIonSilver chloridechemistry.chemical_compoundchemistryElectrodemedicineChloride ionsVoltammetrymedicine.drug
researchProduct

Wearable sensor for real-time monitoring of oxidative stress

Settore ING-IND/23 - Chimica Fisica ApplicataHydrogen peroxide oxidative stress real-time wearable electrochemical sensor exhaled air
researchProduct

Wearable sensor for real-time monitoring of hydrogen peroxide in simulated breath

Hydrogen peroxide electrochemical sensor exhaled air simulated breath real-time
researchProduct

Electrochemical detection of uric acid and ascorbic acid using r-GO/NPs based sensors

2021

Abstract A sensitive and selective electrochemical sensor, based on reduced graphene oxide and gold nanoparticles obtained by simple co-electrodeposition, was developed for the detection of uric acid and ascorbic acid. Because of the electrochemical oxidation of both uric and ascorbic acid depending on the pH, the sensor performances were studied at different pH values. Excellent results were obtained for uric acid detection in a linear range from 10 to 500 µmol dm−3 with a sensitivity of 0.31 µA cm−2 µM−1. A limit of detection and quantification of 3.6 µM and 10.95 µmol dm−3, respectively, was calculated. Sensors showed good selectivity toward different interfering species present in the m…

Detection limitChromatographyGeneral Chemical Engineering02 engineering and technologyUrineUric acid Food010402 general chemistry021001 nanoscience & nanotechnologyAscorbic acid01 natural sciences0104 chemical sciencesElectrochemical gas sensorMatrix (chemical analysis)chemistry.chemical_compoundBody fluidsSettore ING-IND/23 - Chimica Fisica ApplicatachemistryLinear rangeElectrochemical sensorColloidal goldSettore ING-IND/17 - Impianti Industriali MeccaniciElectrochemistryUric acidAscorbic acid0210 nano-technology
researchProduct

Electrochemical detection of dopamine with negligible interference from ascorbic and uric acid by means of reduced graphene oxide and metals-NPs base…

2021

Abstract Dopamine is an important neurotransmitter involved in many human biological processes as well as in different neurodegenerative diseases. Monitoring the concentration of dopamine in biological fluids, i.e., blood and urine is an effective way of accelerating the early diagnosis of these types of diseases. Electrochemical sensors are an ideal choice for real-time screening of dopamine as they can achieve fast, portable inexpensive and accurate measurements. In this work, we present electrochemical dopamine sensors based on reduced graphene oxide coupled with Au or Pt nanoparticles. Sensors were developed by co-electrodeposition onto a flexible substrate, and a systematic investigati…

Dopaminechemistry.chemical_elementMetal NanoparticlesNanotechnologyAscorbic AcidPlatinum nanoparticlesBiochemistryAnalytical Chemistrylaw.inventionlawSettore ING-IND/17 - Impianti Industriali MeccaniciEnvironmental ChemistryHumansElectrodesSpectroscopyPlatinumDetection limitChemistryGrapheneSubstrate (chemistry)Electrochemical TechniquesUric AcidSettore ING-IND/23 - Chimica Fisica ApplicataLinear rangeColloidal goldElectrodeGraphiteGoldDopamine Electrochemical sensor Graphene oxide Metal nanoparticles Neurodegenerative disease UrinePlatinumAnalytica chimica acta
researchProduct

Electrochemical detection of chloride ions using Ag-based electrodes obtained from compact disc

2022

Abstract In this work electrochemical sensors fabricated from compact disc material (waste or new) are used to quantify chloride ions in different types of samples. All three electrodes, working, counter, and pseudo-reference electrodes, were fabricated from the compact disc and directly used. Different parameters were studied in order to demonstrate the possibility of using this waste material for efficient and low-cost electrochemical sensors. Chloride sensing performance was evaluated using linear scan voltammetry as the detection technique. A sensitivity of 0.174 mA mM−1 cm−2 with a limit of detection of 20 μM and excellent selectivity against many interferents was observed. Selectivity…

Detection limitReproducibilityCompact DisksChemistryAnalytical chemistryReproducibility of ResultsElectrochemical TechniquesElectrochemistryBiochemistryChlorideAnalytical ChemistryElectrochemical gas sensorSettore ING-IND/23 - Chimica Fisica ApplicataChloridesChloride ions Compact disc Cystic fibrosis Disposable sensor Electrochemical sensor Real time monitoring Water quality Wearable sensorsElectrodeSettore ING-IND/17 - Impianti Industriali MeccanicimedicineEnvironmental ChemistrySelectivityVoltammetryElectrodesSpectroscopymedicine.drug
researchProduct

Monitoring Risk Factors and Improving Adherence to Therapy in Patients With Chronic Kidney Disease (Smit-CKD Project): Pilot Observational Study

2022

Background Chronic kidney disease is a major public health issue, with about 13% of the general adult population and 30% of the elderly affected. Patients in the last stage of this disease have an almost uniquely high risk of death and cardiovascular events, with reduced adherence to therapy representing an additional risk factor for cardiovascular morbidity and mortality. Considering the increased penetration of mobile phones, a mobile app could educate patients to autonomously monitor cardiorenal risk factors. Objective With this background in mind, we developed an integrated system of a server and app with the aim of improving self-monitoring of cardiovascular and renal risk factors and…

kidneytherapy adherenceintegrated systemSMIT-CKDcardiaccardiovascularhealth appGeneral MedicinemonitoringSettore ING-IND/23 - Chimica Fisica ApplicatamHealthrisk factorcardiologymobile appSettore ING-IND/17 - Impianti Industriali MeccaniciCKDeHealthrenaladherencemobile healthchronic kidney diseaseJMIR Bioinformatics and Biotechnology
researchProduct

FLEXIBLE ELECTRODE BASED ON GOLD NANOPARTICLES AND REDUCED GRAPHENE OXIDE FOR URIC ACID DETECTION USING LINEAR SWEEP VOLTAMMETRY

2021

In this work, an electrochemical sensor for uric acid determination is shown with a preliminary study for its validation in real samples (milk and urine). Uric acid can be electrochemically oxidized in aqueous solutions and thus it is possible to obtain electrochemical sensors for this chemical by means of this electrooxidation reaction. Indium tin oxide coated on flexible polyethylene terephthalate substrate, modified with reduced graphene oxide and gold nanoparticles by co-electrodeposition, was used. Electrodeposition was performed at -0.8V vs SCE for 200 s. All samples were characterized by electron scan microscopy and electron diffraction spectroscopy. A careful investigation on the ef…

TK7885-7895Computer engineering. Computer hardwareMilkChemical engineeringSettore ING-IND/23 - Chimica Fisica ApplicataElectrochemical sensorTP155-156UrineUric acidUric acid Electrochemical sensors Reduced graphene oxide Gold nanoparticles Milk Urine
researchProduct