0000000000369833
AUTHOR
Vaccari A
Approaches and techniques for imaging guided for needle placement in MR Arthrography of the shoulder
SCHWANNOMA PELVICO. ASPETTI TC ED RM IN QUATTRO CASI
Ruolo dell'ecografia dinamica del ginocchio nei volontari e nei pazienti con diagnosi clinica di tendinopatia rotulea
HIGH-RESOLUTION ULTRASONOGRAPHY (HRUS) OF THE MENISCAL CYST OF THE KNEE : OUR EXPERIENCE
Purpose. This study was undertaken to assess the diagnostic accuracy of high-resolution ultrasonography (HRUS) in the detection of meniscal cysts. Materials and methods. Over a 2-year period, 1,857 patients underwent magnetic resonance imaging (MRI) of the knee for traumatic or degenerative disorders. All patients with MRI evidence of a meniscal cyst were studied by HRUS. HRUS was also performed on an equal number of patients without MRI evidence of meniscal cyst who were used as a control group. All HRUS examinations were conducted by a radiologist blinded to the MRI findings. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of HRUS were assesse…