0000000000374649
AUTHOR
Sarah L. Hosking
Performance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability
Aim: The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient’s age on the instrument performance are tested with a series of experiments. Methods: First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error −1.34 (2.72) D) were examined with the C-Quant straylightmeter, taking 10 consecutive readings. Five subjects were also examined on five consecutive days to assess reproducibility. Additionally, repeated measures of straylight from 84 subjects of ages ranging from 19 to 86 years (mean (SD): 42.4 (24.0) years) were retrospectively analysed to assess the …
A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects
A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…
Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye study.
Purpose To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Setting Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Methods Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessi…
Retinal straylight in patients with monofocal and multifocal intraocular lenses
Purpose To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. Setting Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. Methods In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. Re…
Comparison of higher order aberrations measured by NIDEK OPD-Scan dynamic skiascopy and Zeiss WASCA Hartmann-Shack aberrometers.
<h4>PURPOSE</h4><p>To compare the measurement of wavefront aberrations in non-cyclopleged human eyes with Hartmann-Shack and dynamic skiascopy wavefront analyzers.</p> <h4>METHODS</h4><p>Eighty eyes of 40 healthy young adults (19 men, 21 women; mean age 20.8±2.5 years) with refractive errors ranging from +1.50 to –9.75 diopters (D) sphere and up to 1.75 D cylinder (mean spherical equivalent refraction –2.12±2.69 D) were examined with the Zeiss/Meditec WASCA and NIDEK OPD-Scan wavefront analyzers and with the Nippon SRW5000 binocular, open-field autorefractor without the instillation of antimuscarinic agents. Three measurements were taken with each s…