0000000000381407

AUTHOR

Tuomo Nieminen

showing 4 related works from this author

Evaluating the effectiveness and risks of oral anticoagulant treatments in multimorbid frail older subjects with atrial fibrillation using the multid…

2018

Background: Previous studies suggested that a different risk of mortality may influence the oral anticoagulant prescription in older patients with atrial fibrillation (AF). Recently, the Multidimensional Prognostic Index (MPI) demonstrated a high grade of accuracy, calibration and feasibility to predict mortality in hospitalized and community-dwelling older people. Prognostic information, as calculated by the MPI, however, is not included in the decision algorithm of treatments in older patients with AF Purpose: The aim of this international multicenter prospective observational study was to evaluate whether a different prognostic profile, as determined by the MPI, is associated with differ…

medicine.medical_specialtyMuldimensional Prognostic IndexPopulationlaw.invention03 medical and health sciencesElderly0302 clinical medicineRandomized controlled triallawInternal medicineAtrial FibrillationmedicineRisk of mortality030212 general & internal medicineMedical prescriptioneducationAnticoagulants; Atrial Fibrillation; Elderly; Frailty; Muldimensional Prognostic Indexeducation.field_of_studyFrailtybusiness.industryAnticoagulantWarfarinAnticoagulantsAtrial fibrillationmedicine.diseaseRelative riskObservational studyGeriatrics and GerontologybusinessGerontology030217 neurology & neurosurgerymedicine.drugEuropean Geriatric Medicine
researchProduct

Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow-up.

2007

The study was aimed to test the mechanical strength, structural stability, and tissue reactions of optically amorphous and crystalline polyetheretherketone (PEEK) plates during a 3-year follow-up in vivo and in vitro. The injection-moulded PEEK plates were implanted to the dorsal subcutis of 12 sheep, which were sacrificed at 6-156 weeks. Thereafter, the plates were subjected to tensile tests, and levels of crystallinity were assessed by differential scanning calorimetry (DSC). Histological evaluation was carried out using the paraffin technique. In vitro properties were examined with the tensile test and DSC at 0-156 weeks. Tissue reactions were mild and fairly similar for the amorphous an…

Materials scienceYield (engineering)PolymersBiomedical EngineeringBiocompatible MaterialsPolyethylene GlycolsBiomaterialsProsthesis ImplantationCrystallinityBenzophenonesDifferential scanning calorimetryTensile StrengthUltimate tensile strengthMaterials TestingPeekAnimalsAnesthesiaComposite materialTensile testingInflammationSheepMetals and AlloysProstheses and ImplantsKetoneseye diseasesInternal FixatorsAmorphous solidEosinophilsCeramics and Compositessense organsElongationFollow-Up StudiesJournal of biomedical materials research. Part A
researchProduct

In vivo and in vitro degradation of a novel bioactive guided tissue regeneration membrane

2006

The aim of this study was to assess degradation of a novel bioactive guided tissue regeneration (GTR) membrane and to quantify the concurrent tissue responses. Pieces of membrane composed of poly-l-lactide, poly-d,l-lactide, trimethylenecarbonate and polyglycolide were dipped into an N-methyl-2-pyrroline (NMP) solution and implanted in the mandibles of 10 sheep. The animals were sacrificed at 6-104 weeks. Parallel in vitro degradation was analysed by measuring the inherent viscosity, water absorption and remaining mass. One of the 2 in vitro sets of membranes was prehandled with NMP. At 6-26 weeks in vivo, the gradually more degraded implants were surrounded by a fibrous network. At 52 and …

Time FactorsAbsorption of waterPolyglycolideInherent viscosityBiocompatible MaterialsMandiblechemistry.chemical_compoundIn vivoAnimalsMedicineDental ImplantsSheepbusiness.industryRegeneration (biology)Dental Implantation EndosseousMembranes ArtificialAnatomyIn vitroBiodegradation EnvironmentalMembraneOtorhinolaryngologychemistryGuided Tissue Regeneration PeriodontalBiophysicsDegradation (geology)FemaleSurgeryOral SurgerybusinessInternational Journal of Oral and Maxillofacial Surgery
researchProduct

The Duke treadmill score with bicycle ergometer: Exercise capacity is the most important predictor of cardiovascular mortality

2018

Background The Duke treadmill score, a widely used treadmill testing tool, is a weighted index combining exercise time or capacity, maximum ST-segment deviation and exercise-induced angina. No previous studies have investigated whether the Duke treadmill score and its individual components based on bicycle exercise testing predict cardiovascular death. Design Two populations with a standard bicycle testing were used: 3936 patients referred for exercise testing (2371 men, age 56 ± 13 years) from the Finnish Cardiovascular Study (FINCAVAS) and a population-based sample of 2683 men (age 53 ± 5.1 years) from the Kuopio Ischaemic Heart Disease study (KIHD). Methods Cox regression was applied for…

MaleTime FactorsEpidemiologyDuke treadmill score030204 cardiovascular system & hematologyFull Research PaperAngina0302 clinical medicineRisk Factorscardiovascular mortalityCause of DeathMedicine030212 general & internal medicineSegment deviationta315FinlandExercise ToleranceSisätaudit - Internal medicineta3141Exercise capacityTreadmill testingMiddle AgedPrognosisfyysinen kuntoCardiorespiratory FitnessCardiovascular DiseasesCardiologyBody Compositionstress testFemaleBicycle ergometerCardiology and Cardiovascular MedicineRisk PredictionAdultkuolleisuusmedicine.medical_specialtyBiolääketieteet - BiomedicinekuntotestitRisk Assessment03 medical and health sciencesPredictive Value of TestsInternal medicineHumansCardiovascular mortalityAgedbusiness.industryprognostic factorsennusteet217 Medical engineeringmedicine.diseaseBicyclingPhysical Fitness3121 General medicine internal medicine and other clinical medicineExercise Testsydän- ja verisuonitauditStock price indexbusiness
researchProduct