0000000000388153

AUTHOR

Alejandro Cerviño-expósito

Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)

We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…

research product

Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creation.

Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …

research product

Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses

AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. RESULTS: The power distribution of the lenses was affected by pupil siz…

research product

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

research product