Prognostic value of troponin I in atrial fibrillation
To evaluate whether circulating cardiac troponin I (cTnI) levels are associated with worst outcomes in patients with atrial fibrillation (AF).Consecutive patients visiting the emergency room (ER) with a new episode of a previously diagnosed AF or a new diagnosis of AF during ER admission between January 1st, 2010 and December 31st, 2015, were enrolled in the study (n = 2617). After applying exclusion criteria and eliminating repeated episodes, 2013 patients were finally included. Of these, 1080 patients with at least one cTnI measurement in the ER were selected and classified into 4 groups according to cTnI quartiles: Q1 (n = 147) cTnI10 ng/L (Group 1); Q2 (n = 254): 10-19 ng/L (Group 2); Q…
P1193Prognostic value of high sensitive troponin I in patients with atrial fibrillation in the emergency department
P1475Impact of automatic screening and parasternal rights positions in the eligibility of patients with hypertrophic cardiomyopathy for subcutaneous automatic cardioverter defibrillator implant
Abstract Background A high percentage of failures in the detection of QRS and T wave in patients (pts) with hypertrophic cardiomyopathy (HCM) have been reported. This finding would prevent them from being eligible for an implantable subcutaneous automatic defibrillator (S-ICD). However, recently 2 changes in the detection have been proposed, automatic screening and the use of right parasternal position of the lead. The aim of our work was to study if the elegibility proportion of patients was increased with both 2 advacements. Methods We included 31 patients (18 male)with a diagnosis of HCM and at least 1 risk factor for sudden death, in follow-up at the outdoor clinic of of 2 cardiology …
P321Effect of biventricular pacing on ventricular remodeling in asymptomatic heart failure patients with ischemic cardiomyopathy
Sex-Specific Ventricular Arrhythmias and Mortality in Cardiac Resynchronization Therapy Recipients
OBJECTIVES The study goal was to examine whether there are sex-related differences in the incidence of ventricular arrhythmias and mortality in CRT-defibrillator (CRT-D) recipients. BACKGROUND Few studies have evaluated sex-related benefits of cardiac resynchronization therapy (CRT). Moreover, data on sex-related differences in the occurrence of ventricular tachyarrhythmias in this population are limited. METHODS A multicenter retrospective study was conducted in 460 patients (355 male subjects and 105 female subjects) from the UMBRELLA (Incidence of Arrhythmia in Spanish Population With a Medtronic Implantable Cardiac Defibrillator Implant) national registry. Patients were followed up thro…