Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability
Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…
Healon5 versus Viscoat during cataract surgery: intraocular pressure, laser flare and corneal changes
Background: The use of a viscoelastic substance facilitates cataract surgery. Healon 5 is a new viscoelastic product with special rheological properties. We evaluated the postoperative effect of Viscoat and Healon5 on intraocular pressure (IOP), central corneal thickness (CCT), endothelial cell counts and laser flare. Methods: Forty-eight eyes of 48 patients undergoing routine phacoemulsification followed by foldable IOL implantation were enrolled. Either Healon5 or Viscoat was used according to a block- randomization scheme. The aspiration technique was standardized. IOP, CCT, endothelial cell counts and laser flare were compared pre- and postoperatively. Statistical analysis was performed…
Clinical aspects of the apparent diffusion coefficient in 3He MRI: results in healthy volunteers and patients after lung transplantation.
Purpose To measure the apparent diffusion coefficient (ADC) after inhalation of hyperpolarized 3He in healthy volunteers and lung transplant recipients, and demonstrate the gravity dependence of ADC values. Materials and Methods Six healthy volunteers, 10 patients after single-lung transplantation, and six patients after double-lung transplantation were examined at 1.5T during inspiration and expiration. The inhalation of 300 mL of hyperpolarized 3He was performed with a computer-controlled delivery device. A two-dimensional fast low-angle shot (FLASH) sequence measured the 3He diffusive gas movement. From these data the ADC was calculated. Results The mean ADC was 0.143 cm2/second in healt…