Study of a High-Resolution PET System Using a Silicon Detector Probe

2015

253 páginas. Tesis Doctoral del Departamento de Física Atómica, Molecular y Nuclear de la Universidad de Valencia y del Instituto de Física Corpuscular (IFIC).

:FÍSICA [UNESCO]tomografía por emisión de positronesUNESCO::FÍSICAPET Scannerreconstrucción de la imágen médicafísica médicaTomography
researchProduct

Silicon as an Unconventional Detector in Positron Emission Tomography.

2012

Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been a successful in achieving ~5mm FWHM spatial resolution in human studies and ~1mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches. Foremost is it…

PhysicsNuclear and High Energy Physics010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorPhysics::Medical PhysicsPhotodetectorScintillator01 natural sciencesParticle detectorLyso-Article030218 nuclear medicine & medical imagingSemiconductor detector03 medical and health sciences0302 clinical medicineOptics0103 physical sciencesMedical imagingbusinessInstrumentationImage resolutionNuclear instrumentsmethods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
researchProduct

A high-resolution PET demonstrator using a silicon "magnifying glass".

2021

Abstract To assist ongoing investigations of the limits of the tradeoff between spatial resolution and noise in PET imaging, several PET instruments based on silicon-pad detectors have been developed. The latest is a segment of a dual-ring device to demonstrate that excellent reconstructed image resolution can be achieved with a scanner that uses highresolution detectors placed close to the object of interest or surrounding a small field-of-view in combination with detectors having modest resolution at larger radius. The outer ring of our demonstrator comprises conventional BGO block detectors scavenged from a clinical PET scanner and located at a 500 mm radius around a 50 mm diameter field…

ScannerPhotonSiliconchemistry.chemical_elementScintillatorPhysics and Astronomy(all)01 natural sciencesArticle030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticssilicon detectors0103 physical sciencesDetectors and Experimental Techniquesmagnifying PETImage resolutionPhysics010308 nuclear & particles physicsbusiness.industryDetectorResolution (electron density)high-resolution imagingRadiusPETchemistrybusinessPhysics procedia
researchProduct