0000000000408559

AUTHOR

Christian Mewis

showing 2 related works from this author

Rationale for and design of the CREATIVE-AF trial: randomized, double-blind, placebo-controlled, crossover study of the effect of irbesartan on oxida…

2008

Background and objective: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Recent studies suggest there is an angiotensin II-dependent increase in adhesion molecules and oxidative stress parameters during AF. These alterations appear to contribute to inflammatory and prothrombotic changes in the atrial endocardium (‘endocardial remodelling’), suggesting that patients with increased levels of these factors might be at risk of thromboembolic events. The purpose of the CREATIVE-AF (Impact of Irbesartan on Oxidative Stress and C-Reactive Protein Levels in Patients with Persistent Atrial Fibrillation) trial is to prove the principle concept that blockade of angiotensin II type 1 r…

AdultMalemedicine.medical_specialtyAdolescentEndpoint DeterminationTetrazolesmedicine.disease_causeYoung AdultIrbesartanVon Willebrand factorDouble-Blind MethodInternal medicineAtrial FibrillationmedicineHumansPharmacology (medical)Cell adhesionAgedCross-Over StudiesbiologyCell adhesion moleculebusiness.industryPatient SelectionBiphenyl CompoundsAtrial fibrillationGeneral MedicineIrbesartanMiddle Agedmedicine.diseaseAngiotensin IICrossover studyOxidative StressData Interpretation StatisticalSample SizeCardiologybiology.proteinFemalebusinessAngiotensin II Type 1 Receptor BlockersCell Adhesion MoleculesOxidative stressBiomarkersmedicine.drugClinical drug investigation
researchProduct

Gold vs. platinum-iridium tip catheter for cavotricuspid isthmus ablation: the AURUM 8 study

2010

Aims Gold electrodes have the theoretical advantage of creating bigger lesions than platinum–iridium (Pt–Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt–Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. Methods and results A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip…

MaleCavotricuspid isthmusmedicine.medical_specialtymedicine.medical_treatmentCatheter ablation030204 cardiovascular system & hematologyIridium03 medical and health sciences0302 clinical medicineRecurrencePhysiology (medical)medicineHumansFluoroscopyProspective Studies030212 general & internal medicineClinical efficacyElectrodesAgedPlatinumRetrospective Studiesmedicine.diagnostic_testbusiness.industryThermal ConductivityMiddle AgedAblationmedicine.disease3. Good healthSurgeryCatheterTreatment OutcomeAtrial FlutterCatheter AblationFemaleGoldCardiology and Cardiovascular MedicinebusinessAtrial flutterFollow-Up StudiesTip catheterEuropace
researchProduct