0000000000418734

AUTHOR

Saif Afat

0000-0002-6861-6245

showing 6 related works from this author

Accelerated T2-Weighted TSE Imaging of the Prostate Using Deep Learning Image Reconstruction: A Prospective Comparison with Standard T2-Weighted TSE …

2021

Multiparametric MRI (mpMRI) of the prostate has become the standard of care in prostate cancer evaluation. Recently, deep learning image reconstruction (DLR) methods have been introduced with promising results regarding scan acceleration. Therefore, the aim of this study was to investigate the impact of deep learning image reconstruction (DLR) in a shortened acquisition process of T2-weighted TSE imaging, regarding the image quality and diagnostic confidence, as well as PI-RADS and T2 scoring, as compared to standard T2 TSE imaging. Sixty patients undergoing 3T mpMRI for the evaluation of prostate cancer were prospectively enrolled in this institutional review board-approved study between O…

Cancer Researchdiagnostic imagingImage qualityIterative reconstructionArticleprostatic neoplasms030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineProstateMedical imagingmedicineRC254-282Multiparametric Magnetic Resonance Imagingbusiness.industryDeep learningNeoplasms. Tumors. Oncology. Including cancer and carcinogensdeep learningmultiparametric magnetic resonance imagingmedicine.diseasemedicine.anatomical_structureOncology030220 oncology & carcinogenesisArtificial intelligenceNuclear medicinebusinessT2 weightedCancers
researchProduct

Deep learning-accelerated T2-weighted imaging of the prostate: Reduction of acquisition time and improvement of image quality.

2021

Abstract Purpose To introduce a novel deep learning (DL) T2-weighted TSE imaging (T2DL) sequence in prostate MRI and investigate its impact on examination time, image quality, diagnostic confidence, and PI-RADS classification compared to standard T2-weighted TSE imaging (T2S). Method Thirty patients who underwent multiparametric MRI (mpMRI) of the prostate due to suspicion of prostatic cancer were included in this retrospective study. Standard sequences were acquired consisting of T1- and T2-weighted imaging and diffusion-weighted imaging as well as the novel T2DL. Axial acquisition time of T2S was 4:37 min compared to 1:38 min of T2DL. Two radiologists independently evaluated all imaging d…

Malemedicine.medical_specialtyImage qualityLesionDeep LearningProstateMedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective Studiesmedicine.diagnostic_testbusiness.industryDeep learningProstatic NeoplasmsMagnetic resonance imagingRetrospective cohort studyGeneral MedicineMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structureAcquisition timeArtificial intelligenceRadiologymedicine.symptombusinessT2 weightedEuropean journal of radiology
researchProduct

Endovascular stentectomy using the snare over stent-retriever (SOS) technique: An experimental feasibility study

2017

PLoS one 12(5), e0178197 (2017). doi:10.1371/journal.pone.0178197

GlycerolSwinePhysiologylcsh:Medicine030218 nuclear medicine & medical imaging0302 clinical medicinePig ModelsBlood FlowMedicine and Health SciencesMedicinelcsh:ScienceData flow modelClinical scenarioMammalsMultidisciplinaryExperimental DesignEndovascular ProceduresVasospasmAnimal ModelsProsthesis FailureBody FluidsPhysical sciencesChemistryBloodExperimental Organism SystemsResearch DesignVertebratesFemaleStentsRadiologyAnatomyResearch ArticleBiotechnologymedicine.medical_specialtyCathetersSurgical and Invasive Medical ProceduresMonomers (Chemistry)Research and Analysis Methods03 medical and health sciencesAnimal modelText miningIn vivoBlood vessel prosthesisAnimalsHumansPolymer chemistryStent retrieverbusiness.industrylcsh:ROrganismsBiology and Life Sciencesmedicine.diseaseBlood Vessel ProsthesisDisease Models AnimalStent ImplantationAmniotesFeasibility StudiesMedical Devices and Equipmentlcsh:Qbusiness030217 neurology & neurosurgeryPLOS ONE
researchProduct

Early Tumor Size Reduction of at least 10% at the First Follow-Up Computed Tomography Can Predict Survival in the Setting of Advanced Melanoma and Im…

2021

Early tumor size reduction (TSR) has been explored as a prognostic factor for survival in patients with advanced melanoma in clinical trials. The purpose of this analysis is to validate, in a routine clinical milieu, the predictive capacity of TSR by 10% for overall survival (OS) and progression-free survival (PFS) and to compare its predictive performance with the RECIST 1.1 criteria.This retrospective study was approved by the local ethics committee. A total of 152 patients with both CT before immunotherapy initiation and at first response evaluation after immunotherapy initiation were included. Prior to statistical analysis, treatment response was trichotomized as follows: Complete respo…

Oncologymedicine.medical_specialtyContext (language use)030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesProgression-free survivalProspective cohort studyMelanomaRetrospective Studiesbusiness.industryMelanomafungiRetrospective cohort studymedicine.diseaseClinical trialTreatment Outcome030220 oncology & carcinogenesisBiomarker (medicine)ImmunotherapyTomography X-Ray ComputedbusinessProgressive diseaseFollow-Up StudiesAcademic Radiology
researchProduct

Prospective Image Quality and Lesion Assessment in the Setting of MR-Guided Radiation Therapy of Prostate Cancer on an MR-Linac at 1.5 T: A Compariso…

2021

The objective of this study is to conduct a qualitative and a quantitative image quality and lesion evaluation in patients undergoing MR-guided radiation therapy (MRgRT) for prostate cancer on a hybrid magnetic resonance imaging and linear accelerator system (MR-Linac or MRL) at 1.5 Tesla. This prospective study was approved by the institutional review board. A total of 13 consecutive patients with biopsy-confirmed prostate cancer and an indication for MRgRT were included. Prior to radiation therapy, each patient underwent an MR-examination on an MRL and on a standard MRI scanner at 3 Tesla (MRI3T). Three readers (two radiologists and a radiation oncologist) conducted an independent qualita…

0301 basic medicineCancer ResearchIntraclass correlationImage qualityPIRADSFleiss' kappalcsh:RC254-282ArticleLesion03 medical and health sciences0302 clinical medicineimage qualityMedicineEffective diffusion coefficientimage guidanceRadiation oncologistMR-Linacmedicine.diagnostic_testbusiness.industryMagnetic resonance imaginglcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogenslesion detection030104 developmental biologyadaptive radiotherapyOncologyprostate carcinoma030220 oncology & carcinogenesismpMRImedicine.symptombusinessNuclear medicineKappaCancers
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct