Direct chromatographic study of the enantioselective biodegradation of ibuprofen and ketoprofen by an activated sludge
[EN] The quantification of the enantiomeric fraction (EF) during the biodegradation process is essential for environmental risk assessment. In this paper the enantioselective biodegradation of ibuprofen, IBU, and ketoprofen, KET, two of the drugs most consumed, was evaluated. Biodegradation experiments were performed in batch mode using a minimal salts medium inoculated with an activated sludge (collected from a Valencian Waste Water Treatment Plant) and supplemented with the racemate of each compound. The inoculum activity was verified using fluoxetine as reference compound. The experimental conditions used (analyte concentration and volume of inoculum) were chosen according to OECD guidel…
Reversed phase liquid chromatography for the enantioseparation of local anaesthetics in polysaccharide-based stationary phases. Application to biodegradability studies.
[EN] A comprehensive study on the chiral separation of bupivacaine, mepivacaine, prilocaine and propanocaine with eight commercial polysaccharide-based chiral stationary phases (CSPs) in reversed phase conditions compatible with MS detection is performed. Methanol and acetonitrile are used as organic modifiers. Retention and resolution values obtained for each compound in the different CSPs and mobile phases are compared. The polysaccharide-based CSPs tested present different enantioselectivity towards the analytes. From the results, the experimental conditions for determining the enantiomers of bupivacaine, mepivacaine, prilocaine and propanocaine in saline aqueous samples using MS detecti…
Trimeprazine is enantioselectively degraded by an activated sludge in ready biodegradability test conditions
[EN] A great number of available pharmaceuticals are chiral compounds. Although they are usually manufactured as racemic mixtures, they can be enantioselectively biodegraded as a result of microbial processes. In this paper, a biodegradability assay in similar conditions to those recommended in OECD tests of enantiomers of trimeprazine (a phenothiazine employed as a racemate) is carried out. Experiments were performed in batch mode using a minimal salts medium inoculated with an activated sludge (collected from a Valencian Waste Water Treatment Plant, WWTP) and supplemented with the racemate. The concentration of the enantiomers of trimeprazine were monitored by means of a chiral HPLC metho…
Monod-based ‘single-data’ strategy for biodegradation screening tests
Environmental contextObtaining biodegradation data over time can be difficult, especially when dealing with environmental compartments of increasing complexity. We evaluated the possibility of obtaining a full biodegradation depletion curve from a single biodegradation-time experimental measurement, and found that environmental information related to potential chemical persistence can be derived. The applicability of this ‘single-data’ strategy is illustrated using simulated and experimental data for several compounds. AbstractInformation obtained from biodegradability tests, e.g. half-life (t50) or kinetics parameters, is relevant in environmental risk assessment of new chemicals. In thes…
Comparative modelling study on enantioresolution of structurally unrelated compounds with amylose-based chiral stationary phases in reversed phase liquid chromatography-mass spectrometry conditions
[EN] Polysaccharide-based chiral stationary phases (CSPs) are the most used chiral selectors in HPLC. These CSPs can be used in normal, polar organic and aqueous-organic mobile phases. However, normal and polar organic mobile phases are not adequate for chiral separation of polar compounds, for the analysis of aqueous samples and for MS detection. In these situations, reversed phase conditions, without the usual non-volatile additives incompatible with MS detection, are preferable. Moreover, in most of the reported chiral chromatographic methods, retention is too large for routine work. In this paper, the chiral separation of 53 structurally unrelated compounds is studied using three commer…
Modified Gaussian models applied to the description and deconvolution of peaks in chiral liquid chromatography.
Abstract The description of the profiles of chromatographic peaks has been studied extensively, with a large number of proposed mathematical functions. Among them, the accuracy achieved with modified Gaussian models that describe the deviation of an ideal Gaussian peak as a change in the peak variance or standard deviation over time, has been highlighted. These models are, in fact, a family of functions of different complexity with great flexibility to adjust chromatographic peaks over a wide range of asymmetries and shapes. However, an uncontrolled behaviour of the signal may occur outside the region being fitted, forcing the use of different strategies to overcome this problem. In this wo…