0000000000433666

AUTHOR

Grazia Gambarini

showing 4 related works from this author

Study of reliability of TLDs for the photon dose mapping in reactor neutron fields for BNCT

2008

Abstract Photon dose measurements in radiation fields having the proper characteristics for boron neutron capture therapy (BNCT) present several troubles. The thermal neutron flux is very high and produces a significant contribution to the response of most dosimeters. The consistency of photon dose measurements with CaF 2 :Tm and LiF:Mg, Ti thermoluminescent dosimeters has been studied. A method is described for obtaining the gamma dose with TLD-700 and some results are presented to test its reliability.

PhysicsNeutron captureRadiationDosimeterRadiochemistryGamma rayDose profileNeutronThermoluminescent dosimeterRadiationInstrumentationNeutron temperatureRadiation Measurements
researchProduct

LOW DOSE CHARACTERIZATION OF FRICKE GEL DOSIMETERS BY OPTICAL ABSORBANCE AND MR RELAXATION METHODS

2016

Introduction Fricke gel dosimeters allow measurements of 3D dose distributions and can be an effective tool for dosimetry verifications in radiotherapy. Various authors have reported drawbacks of the gels affecting the accuracy in case of low dose measurements. Purpose This study aims at investigating such drawbacks and at establishing the conditions for an optimal use of the gels. Materials and methods Our dosimeters consist of gels infused with a Fricke ferrous sulphate solution combined with xylenol orange (XO). Two kinds of xylenol orange (XO) and two different gelling agents (gelatin from porcine skin and Agarose) were utilized. Gels are red out by light absorption techniques: images o…

Xylenol orangefood.ingredientMaterials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariBiophysicsAnalytical chemistryGeneral Physics and AstronomyGelatin030218 nuclear medicine & medical imagingAbsorbance03 medical and health scienceschemistry.chemical_compoundGel Fricke0302 clinical medicinefoodNuclear magnetic resonanceAgaroseDosimetryRadiology Nuclear Medicine and imagingIrradiationDosimeterSettore FIS/01 - Fisica SperimentaleGeneral MedicineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)WavelengthchemistryFricke gel030220 oncology & carcinogenesisAgarose
researchProduct

Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters

2017

Abstract Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measur…

Xylenol orangeSettore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistry01 natural sciencesSpectral line030218 nuclear medicine & medical imagingIon03 medical and health scienceschemistry.chemical_compound0302 clinical medicineFricke gel dosimeter; MR measurement; Optical absorbance spectra; Radiation; Instrumentation0103 physical sciencesmedicineIrradiationFricke gel dosimeterInstrumentationSettore CHIM/02 - Chimica FisicaRadiationDosimeter010308 nuclear & particles physicsSettore FIS/01 - Fisica SperimentaleRelaxation (NMR)MR measurementSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryFerricAgarosesense organsOptical absorbance spectramedicine.drugRadiation Measurements
researchProduct

Novel GTA-PVA Fricke gels for three-dimensional dose mapping in radiotherapy

2017

Abstract One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiation-sensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels). These formulations suffer from spontaneous-oxidation and diffusion of ferric ions after irradiation; chelating agents such as xylenol-orange significantly reduces the latter. Other gel types consist of dispersed monomers, and rely on radiation-induced cros…

Materials scienceDiffusionThree-dimensional dosimetry Poly-vinyl alcohol Glutaraldehyde Ferrous sulfate Xylenol-orange Spectrophotometry Optical tomography Magnetic resonance imagingFerrous sulfate01 natural sciencesGlutaraldehyde030218 nuclear medicine & medical imagingFerrousThree-dimensional dosimetry03 medical and health scienceschemistry.chemical_compound0302 clinical medicineMagnetic resonance imaging0103 physical sciencesmedicineChelationIrradiationInstrumentationchemistry.chemical_classificationPoly-vinyl alcoholOptical tomographyRadiation010308 nuclear & particles physicsPolymerXylenol-orangeMonomerchemistryChemical engineeringSpectrophotometryFerricGlutaraldehydeFerrous sulfate; Glutaraldehyde; Magnetic resonance imaging; Optical tomography; Poly-vinyl alcohol; Spectrophotometry; Three-dimensional dosimetry; Xylenol-orange; Radiation; Instrumentationmedicine.drugNuclear chemistry
researchProduct