0000000000452479

AUTHOR

Albert González-barnadas

Patient-centered outcomes after surgical treatment of peri-implantitis: a prospective clinical study.

Background: Peri-implantitis is an inflammatory process affecting soft and hard tissues surrounding dental implants, causing progressive marginal bone loss. Peri-implant surgery is the treatment of choice. However, evidence about its impact on patients' quality of life (QoL) is limited. This study aimed to assess pain and QoL in the first seven post-operative days and measure patient satisfaction at the end of this period. Material and methods: A prospective cohort study was conducted in patients with peri-implantitis. Patients reported pain on a visual analogue scale (VAS) ranging from 0 to 100mm every day during the first week after surgery. They then completed the OHIP-14sp questionnaire…

research product

Accuracy and the role of experience in dynamic computer guided dental implant surgery: an in-vitro study

Background To compare the accuracy of implant placement using the conventional freehand method and a dynamic navigation system; to assess the role of the surgeon’s experience in implant placement using these two methods. Material and Methods A randomized in-vitrostudy was conducted. Six resin mandible models and 36 implants were used. Two researchers with differing clinical experience (novice and experienced) placed implants using either the Navident dynamic navigation system (navigation group) or the conventional freehand method (freehand group). Accuracy was measured by overlaying the real position in the postoperative CBCT on the virtual presurgical placement of the implant in a CBCT ima…

research product

Fracture resistance after implantoplasty in three implant-abutment connection designs

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

research product