Thermal response test analysis for U-pipe vertical borehole heat exchangers under groundwater flow conditions
[EN] Conventional models used in the analysis of thermal response test data only consider conduction as heat transfer mechanism. In cases where presence of groundwater is detected, convection heat transmission plays an important role, so its influence must be determined in the calculation of the effective thermal conductivity, usually overestimated in these situations, increasing its value the higher the power injected and the time elapsed. In this work, based on the data collected in a borehole located at UPV (Valencia) in which have been carried out three thermal response tests with different characteristics, has been implemented a variation of the finite line source model introducing an …