0000000000478751

AUTHOR

Francesco Moscato

SUCCESSFUL ARTERO VENOUS FISTULA USING CARDICA C-PORT xA SYSTEM IN AN ELDERLY UREMIC PATIENT. A CASE REPORT.

INTRODUCTION AND AIMS: In artero venous fistula (AVF) hand-sewn anastomoses are considered the gold standard. These are performed generally with a double running suture. These suturing techniques yeld excellent results, despite being time-consuming, difficult to perform with small vessels, and associated with a significant learning curve. These device are intented to enable rapid, precise and reliable anastomoses in AVF without artery cross-clamping. METHODS: We report the case of a male 65 years old uremic patient with serious atherosclerosis that, in local anesthesia, underwent proximal AVF by mechanical anastomosis between cephalic vein and radial artery without arterious cross-clamping.…

research product

TWO STAGE TRANSPOSITION OF BRACHIO-BASILIC ARTERO-VENOUS FISTULA (BBAVF)BY ULTRACISION

research product

Secondary Hyperparathyroidism and renal transplantation.

research product

Isolation & culture of b-like cells from porcine Wirsung duct

research product

Iniziali esperienze sull'impiego di un dispositivo per l'anastomosi vascolare meccanica per le fistolle arterovenose per l'emodialisi.

INTRODUZIONE ED OBIETTIVI Nella costruzione delle fistole artero-venose, il confezionamento manuale dell’anastomosi è il gold standard.Generalmente questa è realizzata con una o due suture a sopraggitto in continua o talora a punti staccati. La tecnica è abbastanza standardizzata,anche se può richiedere una significativa spesa di tempo, specie in presenza di vasi di piccolo calibro, e una curva di apprendimento anche lunga. Riportiamo la nostra esperienza sull’uso di un dispositivo che permette di rendere l’esecuzione di quest’intervento più rapida, precisa e senza il clampaggio preventivo dell’arteria. MATERIALI E METODI Abbiamo impiegato la suturatrice meccanica per il confezionamento di …

research product

Use of monitoring intraoperative parathyroid hormone during parathyroidectomy in patients on waiting list for renal transplantation.

This report describes the use of intraoperative parathyroid hormone (ioPTH) assay during parathyroidectomy for patients with secondary hyperparathyroidism on the waiting list for renal transplantation. The levels of ioPTH were determined among waiting list patients undergoing subtotal parathyroidectomy and tertiary hyperparathyroidism patients undergoing procedures. The levels of ioPTH were significantly reduced at 10 minutes by 59.7,3% among with secondary hyperparathyroidism and 68.9% among tertiary hyperparathyroidism. A 15 minutes it was 85% in secondary hyperparathyroidism and 89.7% in tertiary hyperparathyroidism. A decrement of 50% in basal values at 10 minutes and 85% decrement or m…

research product

GIANT INCISIONAL HERNIA IN THE ELDERLY PATIENT. A RAPID AND SIMPLE SURGICAL TREATMENT

research product

TWO STAGE TRASPOSITION OF BRACHIO-BASILIC ARTERO-VENOUS FISTULA (BBAVF)BY ULTRACISION.

research product

Use of intraoperative parathyroid hormone in waiting list and kidney transplant patients

research product

Vantaggi e limiti dell'approccio laparoscopico nell'addome acuto

INTRODUZIONE ED OBIETTIVI Le condizioni patologiche che possono insorgere con un quadro di addome acuto sono molto numerose ed il loro riconoscimento, nonostante l’affinamento delle procedure diagnostiche, rappresenta sempre una difficile prova anche per il chirurgo più esperto. Grazie alla standardizzazione delle procedure e all’impiego dell’alta tecnologia la laparoscopia trova oggi sempre maggiori indicazioni per risolvere dubbi diagnostici, anche in urgenza. MATERIALI E METODI Viene riportata la nostra esperienza di approccio laparoscopico su 147 pazienti, tutti emodinamicamente stabili, ricoverati con una diagnosi di ingresso di addome acuto. RISULTATI Nel 59% dei casi il trattamento l…

research product

Secondary Hyperparathyroidism and renal tranplantation

research product

VALUTAZIONE ECO-COLOR-DOPPLER DEL RENE TRAPIANTATO. REVIEW DELLA CASISTICA E VALUTAZIONE CRITICA

research product

Use of the monitoring of intraoperative parathyroid hormone during parathyroidectomy in waiting list for renal transplantation patients

research product

Uso del dosaggio del paratormone intraoperatorio nei pazienti sottoposti a paratiroidectomia in lista d'attesa per trapianto renale

research product

Giant incisional hernia in the ederly patient. A Rapid and simple surgical technique

Objectives The aim is to obtain a) a safe procedure to repair the large abdominal defect and reinforce the fragile zones around; b) a simple and rapid technique to reduce the operation time. Materials And Methods Retrospective review of medical records of 72 elderly patients in whom intraperitoneal mesh placement was used between January 1988 and June 2005. Results No intraoperative complication occurred. In the postoperative stage 7 seromas, 4 haematomas, 2 infections occurred, all solved with conservative treatment. Conclusion The incidence of incisional hernia (IH) vary between 1% and 15 %, with increasing risk of recurrence in relation to the age of patients, wound infection, obesity an…

research product