0000000000498265
AUTHOR
Krzysztof Szczurek-katanski
Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction
Introduction The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity sco…
Biodegradable polymer-coated thin strut sirolimus- -eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population.
Background: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular healing. It was sought herein, to determine 1-year clinical follow-up in patients with DM treated with the thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus durable coating everolimus-eluting stent (DP-EES). Methods: Patients were retrospectively analyzed with DM were treated with either a BP-SES (ALEX™, Balton, Poland, n = 670) or a DP-EES (XIENCE™, Abbott, USA, n = 884)…
Bioresorbable polymer-coated thin strut sirolimus-eluting stent vs durable polymer-coated everolimus-eluting stent in daily clinical practice: Propensity matched one-year results from interventional cardiology network registry
Objectives We sought to determine the 1-year clinical follow-up in patients treated with the thin strut (71 μm) bioabsorbable polymer-coated sirolimus-eluting stent (BP-SES) vs durable coating everolimus eluting stent (DP-EES) in daily clinical routine. Background Presence of durable polymers may be associated with late/very late stent thrombosis occurrence and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. Methods Interventional Cardiology Network Registry is a prospective, multicenter, observational registry of 21,400 consecutive patients treated with PCI since 2010. We analyzed 4,670 patients treated …