0000000000505768

AUTHOR

S. Stengel

showing 4 related works from this author

Premature termination of epidural analgesia—A prospective analysis to improve quality

2009

Summary Background and objective Epidural analgesia (EA) is a gold-standard in post-operative pain control. Therefore, modern treatment concepts targeting early patient recovery regularly implement EA. Due to its increasing impact, EA should meet high quality standards in respect to application and maintenance. Though, daily practice often reveals EA-related problems, our investigation aimed to improve EA quality by assessing incidence and reasons of undeliberate, premature termination of post-operative EA. Methods In the first step all patients with post-operative EA were retrospectively studied covering a 6-month period (group 1). We analysed incidences and reasons of undeliberate termina…

Local anaestheticbusiness.industryIncidence (epidemiology)Motor impairmentContinuous analysisProspective analysisCatheterAnesthesiology and Pain MedicinePain controlAnesthesiaDaily practiceEmergency MedicineMedicinebusinessAcute Pain
researchProduct

Detector response of Cherenkov radiators for calorimetry in the energy range below 14 MeV

2020

Abstract A study of the detector response of PbF 2  crystals and three different types of lead glass blocks to electrons from a 14-MeV beam of the Mainz Microtron MAMI is presented. For the first time, signal height, signal width, and homogeneity of the response of these Cherenkov radiators were determined for energies between 10 and 14 MeV. To complement the beam tests, optical properties of the materials, in particular measured transmittances in the near UV and visible spectrum, were studied. The measured detector responses were also compared to Monte Carlo simulations of energy-loss, light production, transport, and detection. These Cherenkov radiators are considered as active material o…

PhysicsNuclear and High Energy Physics010308 nuclear & particles physicsbusiness.industryDetectorMonte Carlo methodSignal WidthElectron01 natural sciencesLead glassOpticsvisual_art0103 physical sciencesvisual_art.visual_art_mediumPhysics::Accelerator PhysicsNuclear Experiment010306 general physicsbusinessInstrumentationLight dark matterMicrotronCherenkov radiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Electron beam studies of light collection in a scintillating counter with embedded fibers

2021

The light collection of several fiber configurations embedded in a box-shaped plastic scintillating counter was studied by scanning with minimum ionizing electrons. The light was read out by silicon photomultipliers at both ends. The light yield produced by the 855-MeV beam of the Mainz Microtron showed a strong dependence on the transverse distance from the beam position to the fibers. The observations were modeled by attributing the collection of indirect light inside of the counter and of direct light reaching a fiber to the total light yield. The light collection with fibers was compared to that of a scintillating counter without fibers. These studies were carried out within the develop…

PhysicsNuclear and High Energy PhysicsRange (particle radiation)Physics - Instrumentation and DetectorsPhysics::Instrumentation and Detectorsbusiness.industryFOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)ElectronOpticsSilicon photomultiplierCathode rayPhysics::Accelerator PhysicsFiberNuclear Experiment (nucl-ex)businessNuclear ExperimentInstrumentationLight dark matterMicrotronBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Operation and characterization of a windowless gas jet target in high-intensity electron beams

2021

Abstract A cryogenic supersonic gas jet target was developed for the MAGIX experiment at the high-intensity electron accelerator MESA. It will be operated as an internal, windowless target in the energy-recovering recirculation arc of the accelerator with different target gases, e.g., hydrogen, deuterium , helium, oxygen, argon, or xenon. Detailed studies have been carried out at the existing A1 multi-spectrometer facility at the electron accelerator MAMI. This paper focuses on the developed handling procedures and diagnostic tools, and on the performance of the gas jet target under beam conditions. Considering the special features of this type of target, it proves to be well suited for a n…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsNuclear engineeringchemistry.chemical_elementFOS: Physical sciencesElectron01 natural scienceslaw.inventionXenonlaw0103 physical sciencesNuclear Experiment (nucl-ex)010306 general physicsInstrumentationNuclear ExperimentHeliumPhysicsJet (fluid)Argon010308 nuclear & particles physicsParticle acceleratorInstrumentation and Detectors (physics.ins-det)chemistryPhysics::Accelerator PhysicsElectron scatteringBeam (structure)
researchProduct