0000000000509319

AUTHOR

P. Petkov

showing 12 related works from this author

New developments on the recoil distance doppler-shift method

2010

Absolute transition probabilities are fundamental observables for nuclear structure. The recoil-distance-Doppler-shift (RDDS) technique, also called plunger technique, is a well established tool for the determination of these important experimental quantities via the measurement of lifetimes of excited nuclear states. Nowadays nuclear structure investigations are concentrated on exotic nuclei which are often produced with extremely small cross sections or with very low beam intensities. In order to use the RDDS technique also for the investigation of very exotic nuclei this method has to be adapted to the specific needs of these special reactions. This article gives an overview on recent RD…

PhysicsHistoryProjectileNuclear TheoryNuclear structureObservableCoulomb excitationComputer Science ApplicationsEducationNuclear physicsRecoilExcited stateCoulombPhysics::Accelerator PhysicsAtomic physicsNuclear ExperimentBeam (structure)Journal of Physics: Conference Series
researchProduct

Backbending in the pear-shaped 223(90)Th nucleus: Evidence of a high-spin octupole to quadrupole shape transition in the actinides

2017

International audience; Relatively neutron-rich thorium isotopes lie at the heart of a nuclear region of nuclei exhibiting octupole correlation effects. The detailed level structure of Th223 has been investigated in measurements of γ radiation following the fusion-evaporation channel of the Pb208(O18,3n)Th223 reaction at 85 MeV beam energy. The level structure has been extended up to spin 49/2, and 33 new γ rays have been added using triple-γ coincidence data. The spins and parities of the newly observed states have been confirmed by angular distribution ratios. In addition to the two known yrast bands based on a K=5/2 configuration, a non-yrast band has been established up to spin 35/2. We…

octupole correlationNuclear Theorytoriumpear-shaped nuclei[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Nuclear Experiment
researchProduct

A new recoil distance technique using low energy coulomb excitation in inverse kinematics

2011

Abstract We report on the first experiment combining the Recoil Distance Doppler Shift technique and multistep Coulomb excitation in inverse kinematics at beam energies of 3–10 A MeV. The setup involves a standard plunger device equipped with a degrader foil instead of the normally used stopper foil. An array of particle detectors is positioned at forward angles to detect target-like recoil nuclei which are used as a trigger to discriminate against excitations in the degrader foil. The method has been successfully applied to measure lifetimes in 128Xe and is suited to be a useful tool for experiments with radioactive ion beams.

PhysicsPlungerNuclear and High Energy PhysicsInverse kinematicsPhysics::Instrumentation and DetectorsDetectorCoulomb excitationsymbols.namesakeRecoilsymbolsPhysics::Accelerator PhysicsAtomic physicsNuclear ExperimentInstrumentationDoppler effectFOIL methodBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The impact of conversion on the risk of major complication following laparoscopic colonic surgery: an international, multicentre prospective audit.

2018

BACKGROUND: Laparoscopy has now been implemented as a standard of care for elective colonic resection around the world. During the adoption period, studies showed that conversion may be detrimental to patients, with poorer outcomes than both laparoscopic completed or planned open surgery. The primary aim of this study was to determine whether laparoscopic conversion was associated with a higher major complication rate than planned open surgery in contemporary, international practice.METHODS: Combined analysis of the European Society of Coloproctology 2017 and 2015 audits. Patients were included if they underwent elective resection of a colonic segment from the caecum to the rectosigmoid jun…

Laparoscopic surgeryMaleColorectal cancermedicine.medical_treatmentsurgery0302 clinical medicinePostoperative ComplicationsMedicineMajor complicationProspective StudiesLaparoscopySHORT-TERM OUTCOMESColectomyMedical Auditmedicine.diagnostic_testProspective auditGastroenterologyMiddle Agedlaparoscopic surgeryConversion to Open SurgeryColon cancerTreatment OutcomeElective Surgical Procedures030220 oncology & carcinogenesis030211 gastroenterology & hepatologyFemaleColonic surgeryAdultmedicine.medical_specialtyCLINICAL-TRIALNOOPEN COLECTOMY03 medical and health sciencesCOLORECTAL SURGERYCase mix indexgastrointestinal surgeryHumansrectal cancerRECTAL-CANCERAgedta3126business.industryElective resectionmedicine.diseaseRANDOMIZED-TRIALOPEN RESECTIONSurgeryColon cancer; gastrointestinal surgery; laparoscopic surgery; rectal cancer; surgery; GastroenterologyLaparoscopybusinessColorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland
researchProduct

Collectivity and Configuration Mixing inPb186,188andPo194

2006

Lifetimes of prolate intruder states in {sup 186}Pb and oblate intruder states in {sup 194}Po have been determined by employing, for the first time, the recoil-decay tagging technique in recoil distance Doppler-shift lifetime measurements. In addition, lifetime measurements of prolate states in {sup 188}Pb up to the 8{sup +} state were carried out using the recoil-gating method. The B(E2) values have been deduced from which deformation parameters vertical bar {beta}{sub 2} vertical bar =0.29(5) and vertical bar {beta}{sub 2} vertical bar =0.17(3) for the prolate and the oblate bands, respectively, have been extracted. The results also shed new light on the mixing between different shapes.

PhysicsNuclear physicsRecoilDeformation (mechanics)General Physics and AstronomyHigh Energy Physics::ExperimentBeta (velocity)State (functional analysis)Prolate spheroidElectronic band structureMolecular physicsMixing (physics)Radioactive decayPhysical Review Letters
researchProduct

Evaluating the incidence of pathological complete response in current international rectal cancer practice: the barriers to widespread safe deferral …

2018

INTRODUCTION: The mainstay of management for locally advanced rectal cancer is chemoradiotherapy followed by surgical resection. Following chemoradiotherapy, a complete response may be detected clinically and radiologically (cCR) prior to surgery or pathologically after surgery (pCR). We aim to report the overall complete pathological response (pCR) rate and the reliability of detecting a cCR by conventional pre-operative imaging.METHODS: A pre-planned analysis of the European Society of Coloproctology (ESCP) 2017 audit was performed. Patients treated by elective rectal resection were included. A pCR was defined as a ypT0 N0 EMVI negative primary tumour; a partial response represented any r…

MaleColorectal cancerdeferral of surgery; neoadjuvant therapy; pathology; radiology; rectal cancer; Rectal surgery; surgical oncology; Gastroenterology0302 clinical medicineProspective StudiesProspective cohort studyComplete responseMedical Auditintegumentary systemIncidence (epidemiology)IncidenceRemission InductionGastroenterologyMiddle AgedMagnetic Resonance ImagingPeer reviewEuropeTreatment Outcomedeferral of surgeryResponse Evaluation Criteria in Solid Tumors030220 oncology & carcinogenesisPreoperative Period030211 gastroenterology & hepatologyFemaleAdultmedicine.medical_specialtyRectal surgeryNO03 medical and health sciencessurgical oncologymedicineHumansneoadjuvant therapyIntensive care medicineDeferralrectal cancerPathologicalResponse Evaluation Criteria in Solid TumorsAgedNeoplasm Stagingta3126business.industryRectal NeoplasmsReproducibility of ResultsChemoradiotherapy Adjuvantmedicine.diseaseradiologyRectal Neoplasms/diagnostic imagingpathologyNeoplasm Staging/methodsbusiness
researchProduct

An international multicentre prospective audit of elective rectal cancer surgery; operative approach versus outcome, including transanal total mesore…

2018

Introduction: Transanal total mesorectal excision (TaTME) has rapidly emerged as a novel approach for rectal cancer surgery. Safety profiles are still emerging and more comparative data is urgently needed. This study aimed to compare indications and short-term outcomes of TaTME, open, laparoscopic, and robotic TME internationally. Methods: A pre-planned analysis of the European Society of Coloproctology (ESCP) 2017 audit was performed. Patients undergoing elective total mesorectal excision (TME) for malignancy between 1 January 2017 and 15 March 2017 by any operative approach were included. The primary outcome measure was anastomotic leak. Results: Of 2579 included patients, 76.2% (1966/257…

MaleLaparoscopic surgerymedicine.medical_specialtyColorectal cancermedicine.medical_treatmentOperative TimeAnastomosisMalignancyrectal cancer ; laparoscopic surgery ; TME ; transanal TME ; TaTME ; robotic surgery ; randomized clinical-trial ; short-term outcomes ; laparoscopic-assisted resection ; pathological outcomes ; anastomotic leakage ; initial-experience ; riskNO03 medical and health sciencesPostoperative Complications0302 clinical medicineRobotic Surgical Proceduresrobotic surgerytransanal TMEHumansMedicineRobotic surgeryProspective Studieslaparoscopic surgery; Rectal cancer; robotic surgery; TaTME; TME; transanal TME; GastroenterologyRectal cancerAgedTransanal Endoscopic Surgeryta3126Medical AuditUnivariate analysisProctectomyRectal Neoplasmsbusiness.industryRectumGastroenterologyTMEMargins of ExcisionMiddle Agedmedicine.diseaseTotal mesorectal excisionTaTMElaparoscopic surgerySurgeryTreatment OutcomeElective Surgical Procedures030220 oncology & carcinogenesisRectal cancer surgeryFemaleLaparoscopy030211 gastroenterology & hepatologybusiness
researchProduct

Measurement of thett¯production cross section inpp¯collisions ats=1.96  TeVusing soft electronb-tagging

2010

The authors present a measurement of the t{bar t} production cross section using events with one charged lepton and jets from p{bar p} collisions at a center-of-mass energy of 1.96 TeV. A b-tagging algorithm based on the probability of displaced tracks coming from the event interaction vertex is applied to identify b quarks from top decay. Using 318 pb{sup -1} of data collected with the CDF II detector, they measure the t{bar t} production cross section in events with at least one restrictive (tight) b-tagged jet and obtain 8.9{sub -1.0}{sup +1.0}(stat.){sub -1.0}{sup +1.1}(syst.) pb. The cross section value assumes a top quark mass of m{sub t} is presented in the paper. This result is cons…

Top quarkCollider physicsHadronTevatronGeneral Physics and AstronomyElementary particleKinematicsElectronJet (particle physics)01 natural sciences7. Clean energyParticle identificationlaw.inventionlawInvariant massFermilabNuclear ExperimentQuantum chromodynamicsPhysicsLarge Hadron ColliderLuminosity (scattering theory)Supersymmetryb-taggingHadronizationTransverse planeProduction (computer science)Collider Detector at FermilabQuarkSemileptonic decayNuclear and High Energy PhysicsParticle physicsBar (music)Astrophysics::High Energy Astrophysical PhenomenaBottom quarkMeasure (mathematics)Standard ModelNuclear physicsCross section (physics)Particle decay0103 physical sciencesCollider010306 general physicsCompact Muon SolenoidMuonBranching fraction010308 nuclear & particles physicsHigh Energy Physics::PhenomenologyMultiplicity (mathematics)FermionVertex (geometry)Pair productionHigh Energy Physics::ExperimentEnergy (signal processing)Bar (unit)LeptonPhysical Review D
researchProduct

Low-lying electromagnetic transition strengths in 180 Pt

2018

Lifetime measurements have been performed using the 98 Mo ( 86 Kr , 4 n ) 180 Pt reaction at a beam energy of 380 MeV, and the recoil distance Doppler-shift method. In a second experiment the 168 Yb ( 16 O , 4 n ) 180 Pt reaction at a beam energy of 88 MeV using the Ge-gated γ − γ fast timing technique was used to determine lifetimes. Lifetimes of the four lowest yrast states of 180 Pt have been determined. The experimental data are compared to calculations within the framework of the interacting boson model and the general collective model. Both models predict a deformed ground state and are consistent with all the remaining experimental results. peerReviewed

electromagnetic transitionNuclear Experiment
researchProduct

Lifetimes of intruder states in 186Pb, 188Pb and 194Po

2008

Abstract Lifetimes of prolate intruder states in 186Pb and 188Pb and oblate intruder states in 194Po have been determined through recoil distance Doppler-shift lifetime measurements. Deformation parameters of | β 2 | = 0.29 ( 5 ) and | β 2 | = 0.17(3) have been extracted from experimental B ( E 2 ) values for the prolate and the oblate bands, respectively. The present study addresses the phenomenon of shape coexistence typical for the nuclei near Z = 82 and N = 104 , providing information on configuration mixing of intrinsic structures of the nuclei of interest. The results are compared with the available lifetime data and theoretical results for neutron-deficient Po, Pb, Hg and Pt nuclei. …

Nuclear reactionPhysicsNuclear and High Energy Physics21.10.Tg; 23.20.Lv; 27.70.+q; 27.80.+wquadrupole moment[PHYS.NUCL]Physics [physics]/Nuclear Theory [nucl-th]010308 nuclear & particles physics114Cd(83Kr 3n)Prolate spheroid7. Clean energy01 natural sciencesdeformation parametersE=340–375 MeVRecoil108Pd106Pd0103 physical sciencesQuadrupoleOblate spheroidDeformation (engineering)Atomic physics010306 general physicsnuclear reactionsMixing (physics)
researchProduct

Lifetime measurements in mirror nuclei31S and31P: A test for isospin mixing

2011

Using the 20Ne + 12C fusion-evaporation reaction at E20Ne = 33 MeV and the multidetector array GASP in conjuction with the EUCLIDES charged particle detector, angular correlations of coincident pairs of γ transitions and lifetimes in mirror nuclei 31S and 31P have been measured at the Piave-Alpi accelerator of the Laboratori Nazionali di Legnaro. A comparison of the determined B(E1) strengths of the analog mirror 7/2− → 5/2+ transitions indicates the presence of a violation of isospin symmetry.

PhysicsHistoryCarbon-12Symmetry (physics)Charged particleComputer Science ApplicationsEducationNuclear physicsIsotopes of neonCoincidentIsospinPhosphorus-31 NMR spectroscopyMirror nucleiAtomic physicsJournal of Physics: Conference Series
researchProduct

AGATA-Advanced GAmma Tracking Array

2012

WOS: 000300864200005

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPulse-shape and gamma-ray tracking algorithmsFOS: Physical sciencesSemiconductor detector performance and simulationsIntegrated circuit[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Tracking (particle physics)gamma-Ray tracking01 natural sciencesPulse-shape and γ-ray tracking algorithmslaw.inventionData acquisitionlaw0103 physical sciencesddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)010306 general physicsγ-Ray spectroscopyNuclear ExperimentInstrumentationDigital signal processingEvent reconstructiongamma-Ray spectroscopyPhysicssezeleSpectrometerSpectrometers010308 nuclear & particles physicsbusiness.industryDetectorAGATA Digital signals HPGe detectors Pulse-shape Ray trackingHPGe detectorsAlgorithms Crystals Germanium Semiconductor detectors Signal processing Spectrometry Tracking (position)γ-Ray trackingInstrumentation and Detectors (physics.ins-det)Digital signal processingAGATAFísica nuclearbusinessAGATAComputer hardware
researchProduct