0000000000512943

AUTHOR

E. Simon

showing 5 related works from this author

Abstract of the 68th Meeting (Spring Meeting) 6–9 March 1990, Heidelberg

1990

0303 health sciencesPhysiologyChemistryClinical BiochemistryTibialis AnteriorHuman physiology030204 cardiovascular system & hematologyPharmacologySpring (mathematics)ArticleAtrial Natriuretic Peptide03 medical and health sciences0302 clinical medicineAtrial natriuretic peptidePhysiology (medical)Spreading DepressionCapsaicinExtensor Digitorum Longus030304 developmental biologyPflugers Archiv
researchProduct

Interpretation of the Anomalous NaI Events

2001

Anomalous events, with scintillation decay times shorter than nuclear recoils, have been observed by the UKDMC and Saclay NaI experiments. By using the event categories observed in the EDELWEISS experiment, we propose to interpret the anomalous NaI events as surface nuclear recoils accompanied with a small energy loss of an escaping alpha particle. The discrimination performances of the NaI experiments which have not taken into account these events in their analysis, notably for axial WIMP interactions, must then be reevaluated.

Nuclear physicsPhysicsScintillationEnergy lossWIMPPhysics::Instrumentation and DetectorsAstrophysics::Instrumentation and Methods for AstrophysicsAlpha particleEDELWEISSEvent (particle physics)Interpretation (model theory)
researchProduct

Status of the EDELWEISS experiment

1999

The Edelweiss Dark Matter Experiment is installed in the Modane Underground Laboratory since 1994. In 1997 the first detector of a 70 g heat and ionization Ge low-temperature detector built by the collaboration showed its discrimination capabilities. During the last two years the installation was upgraded, and a new generation of 70 g Ge detectors is operational. The detector environment is drastically controlled to avoid radioactive contamination. A test run with two new 70 g detectors shows a reduction by a factor of ten in the background level before 7-ray rejection which is now around 2 events/kg/keV/day. Three 320 g Ge cryogenic detectors have been constructed and are now being tested …

CryostatPhysicsNuclear and High Energy Physics[SDU.ASTR]Sciences of the Universe [physics]/Astrophysics [astro-ph]Dark matterBolometerDetectorCosmic rayEDELWEISSAtomic and Molecular Physics and OpticsParticle detectorlaw.invention[PHYS.ASTR.CO]Physics [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]Nuclear physicsWIMPlaw[SDU]Sciences of the Universe [physics]Measuring instrumentInstrumentationEvent (probability theory)
researchProduct

Republication de: recommandations formalisées d'experts. Prise en charge de la patiente avec une pré-éclampsie sévère–RFE communes Société française …

2022

International audience; Objective: To provide national guidelines for the management of women with severe preeclampsia. Design: A consensus committee of 26 experts was formed. A formal conflict of interest (COI) policy was developed at the onset of the process and enforced throughout. The entire guidelines process was conducted independently of any industrial funding. The authors were advised to follow the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE®) system to guide assessment of quality of evidence. The potential drawbacks of making strong recommendations in the presence of low-quality evidence were emphasized. Methods: The last SFAR and CNGO…

medicine.medical_specialtySevere preeclampsiaEclampsiabusiness.industry[SDV]Life Sciences [q-bio]Neonatal morbidityObstetrics and GynecologyEvidence-based medicineGuidelinesmedicine.diseaseSevere preeclampsiaClinical PracticeQuality of evidence[SDV] Life Sciences [q-bio]Reproductive MedicineIntensive careFamily medicineAnesthesiologymedicineGrading (education)businessMaternal morbidity
researchProduct

Background discrimination capabilities of a heat and ionization germanium cryogenic detector

2001

The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the signal, provided that the background events distribution is not biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data taken in a relatively important radioactive environment show an extra population slightly overlapping the signal. This background is likely due to interactions o…

Dark matterPopulationFOS: Physical sciencesAstrophysicsEDELWEISSAstrophysics01 natural scienceslaw.inventionNuclear physics[PHYS.ASTR.CO]Physics [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]RecoillawIonization0103 physical sciencesNeutron010306 general physicseducationPhysicseducation.field_of_study[SDU.ASTR]Sciences of the Universe [physics]/Astrophysics [astro-ph]010308 nuclear & particles physicsBolometerDetectorAstrophysics (astro-ph)Astronomy and AstrophysicsDark matter ; WIMP ; cryogenic detector
researchProduct