0000000000524830

AUTHOR

Naroa Lozano-carrascal

Effect of implant macro-design on primary stability: A prospective clinical study

Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…

research product

Short implants (8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: A meta-analysis of RCT`s in humans.

Background One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high survival rate of implants placed next to sinus elevation, this technique presents complications that can be avoided by placing short implants, an option that also presents high survival rates. For this reason, the aim of this study is to compare the survival rate, marginal bone loss and complications associated with short implants (<8 mm) versus longer implants (≥8mm) placed with lateral sinus floor elevation in posterior atrophic maxillae. Material and Methods A literature search was conducted …

research product

Evaluation of endovenous sedation using BIS monitoring in dentistry. A systematic review

Background The aim of the present review was evaluate the utility and validity of the Bispectral Index (BIS) in dental treatment carried out under endovenous sedation, and compare its efficacy with clinical sedation scales. Material and Methods Electronic and manual literature searches were conducted by two independent reviewers for articles published up to April 2017 in several databases, including Medline and Cochrane Library. Results Sixteen articles met the inclusion criteria. A correlation was identified between BIS and clinical sedation scales. A BIS range between 75 and 84 showed a high probability of corresponding to an Observer’s Assessment of Alertness and Sedation Scale (OAA/S) v…

research product