0000000000527774

AUTHOR

G. Tinè

showing 5 related works from this author

Effects of the electromagnetic disturbances in the DAQ-based measurement instruments and their compensation

2008

researchProduct

A procedure to evaluate the electromagnetic immunity degree of a data acquisition system

2007

EMCimmunity
researchProduct

Characterization of the Magnetic Induction Field produced by Secondary Substations

2014

The aim of this paper is to develop a methodology for measuring the magnetic field distribution around the prefabricated secondary substations in vibrated reinforced concrete, as well as the definition of a methodology to determining the maximum value of magnetic induction produced by the substations in correspondence to nominal current of the transformer. As proposed has been developed in conformity with laws and standards and can be applied to active and passive secondary substations. The experimental validation of the proposed methodology, carried out by a measurements campaign whose results are reported, confirms the validity and returns a versatile and simple tool for the verification …

distance of first approximation (DPA).distribution substationfield measurements of magnetic inductionhuman exposureSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricifield measurements of magnetic induction human exposure distribution substation distance of first approximation (DPA).Settore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Characterization of Medium Voltage Cables for Power Line Communication

2007

researchProduct

DC series arc faults in PV systems. Detection methods and experimental characterization

2020

This work is focused on the arc faults phenomenon in DC photovoltaic (PV) systems. The paper gives an overview of arc detection methods proposed in literature and presents a preliminary experimental characterization of the arcing current, focusing the attention on series arcs, whose detection is particularly challenging. Experimental tests are carried out, both in laboratory and on field, in order to investigate some relevant characteristics in the arcing current, which can be feasible for the arc detection purpose. Both arcing and non-arcing current signals are acquired and compared in both time and frequency domain. On-field measurements are carried out on a real photovoltaic system, in a…

PV systemsArc faultTheoryofComputation_ANALYSISOFALGORITHMSANDPROBLEMCOMPLEXITYseries arc-faultphotovoltaic cellsSettore ING-INF/07 - Misure Elettriche E Elettronichefault detectionMathematicsofComputing_DISCRETEMATHEMATICS
researchProduct