0000000000537262

AUTHOR

Philipp Appelmann

Screw fixation of radial head fractures: Compression screw versus lag screw—A biomechanical comparison

Abstract Introduction Secondary loss of reduction and pseudarthrosis due to unstable fixation methods remain challenging problems of surgical stabilisation of radial head fractures. The purpose of our study was to determine whether the 3.0 mm Headless Compression Screw (HCS) provides superior stability to the standard 2.0 mm cortical screw (COS). Materials and methods Eight pairs of fresh frozen human cadaveric proximal radii were used for this paired comparison. A standardised Mason II-Fracture was created with a fragment size of 1/3 of the radial head's articular surface that was then stabilised either with two 3.0 mm HCS (Synthes) or two 2.0 mm COS (Synthes) according to a randomisation …

research product

Influence of implant and screw type on local bone strain field: a preliminary study

research product

Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…

research product

The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.

Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…

research product

Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis

In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae feat…

research product