Stellenwert der Spirometertriggerung für die hochauflösende Computertomographie der Lunge in Inspiration und Exspiration

1998

PURPOSE To compare mean lung density (MLD) of paired inspiratory and expiratory thin-section CT scans acquired after patient instruction or using spirometric gating. MATERIALS AND METHODS 21 patients (13 m, 8 f. median age 59 years, two with normal lung function, 15 with obstructive, 4 with restrictive impairment) underwent thin-section CT. Paired inspiratory and expiratory scans were performed in the upper, middle and lower lung fields. They were acquired after automatic patient instruction with constant intervals between instruction and scan. Spirometrically gated scans were acquired within 4 days at 80% and 20% of vital capacity (VC) which has been determined on the CT scanner in supine …

Semiautomatic segmentationSpirometrymedicine.medical_specialtySupine positionLungmedicine.diagnostic_testbusiness.industryRespiratory diseaseGatingmedicine.diseasePulmonary function testingmedicine.anatomical_structureMedicineRadiology Nuclear Medicine and imagingRadiologyExpirationbusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Lack of mutagenic and co-mutagenic effects of magnetic fields during magnetic resonance imaging

2001

Mutagenic and co-mutagenic effects of static, pulsed bipolar gradient, and high-frequency magnetic fields, as well as combinations of them, were examined using the Ames test. The Ames test using Salmonella typhimurium bacteria, wild-type strain RTA, preincubation assay, without metabolic activation, was performed. All combinations of magnetic fields were tested with and without co-exposure to N-methyl-N′-nitro-N-nitrosoguanidine and benzo[a]pyrene-4,5-oxide, ethylene oxide, carboplatin, or cisplatin. As expected, chemical mutagens caused a clear-cut increase of the revertants in the Ames test. However, neither the static fields nor a combination of a static magnetic field with the time-vary…

Salmonella typhimuriumChemical mutagensmedicine.diagnostic_testStrain (chemistry)Mutagenicity TestsChemistryfungifood and beveragesMagnetic resonance imagingEnvironmental Exposureequipment and suppliesMagnetostaticsMagnetic Resonance ImagingMagnetic fieldAmes testElectromagnetic FieldsNuclear magnetic resonanceMutagenesismedicineAnimalsRadiology Nuclear Medicine and imaginghuman activitiesJournal of Magnetic Resonance Imaging
researchProduct

Ultraschnelle MRT der Lungenventilation mittels hochpolarisiertem Helium-3*

2000

Objective Assessment of the temporal and spatial dynamics of hyperpolarized Helium-3 (3He) distribution in the lung with ultrafast gradient-echo magnetic-resonance imaging. Material and methods Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE = 3.3 ms/1.3 ms (slice thickness, 40 mm) and TR/TE = 2.0 ms/0.7 ms (without slice selection). A series of 80 or 160 projection images was obtained with 210 ms or 130 ms temporal resolution, respectively. Imaging was performed during several respiratory cycles after application of a single bolus of 300 mL hyperpolarized 3He. Measurements were performed in six healthy volunteers (spontaneous breathing). Re…

Lungmedicine.anatomical_structureNuclear magnetic resonanceMaterials sciencePulse (signal processing)Temporal resolutionBreathingmedicineWashoutRadiology Nuclear Medicine and imagingHyperpolarized Helium 3Image resolutionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes

2000

MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…

Lungbusiness.industryEthics committeeSmoking historyPulmonary function testingCorrelationmedicine.anatomical_structureHealthy volunteersBreathingmedicineMolecular MedicineRadiology Nuclear Medicine and imagingLung volumesNuclear medicinebusinessSpectroscopy
researchProduct

Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

2000

This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal – not diffuse – airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six o…

AdultLung DiseasesMalemedicine.medical_specialtyAdolescentHigh resolutionSeverity of Illness IndexPulmonary function testingHumansMedicineRadiology Nuclear Medicine and imagingLung volumesProspective StudiesAgedNeuroradiologyAged 80 and overLungbusiness.industryRespirationUltrasoundGeneral MedicineNormal lung functionMiddle AgedRespiratory Function TestsLung densitymedicine.anatomical_structureFemaleRadiologyBlood Gas AnalysisArtifactsTomography X-Ray ComputedbusinessEuropean Radiology
researchProduct