0000000000544565

AUTHOR

Christoph Hirneiß

showing 2 related works from this author

Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields

2014

To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…

AdultMaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOptic DiskVision DisordersVisual AcuityNerve fiber layerGlaucomalaw.inventionTonometry OcularCellular and Molecular Neurosciencechemistry.chemical_compoundNerve FiberslawOphthalmologymedicineHumansProspective StudiesIntraocular PressureHeidelberg retina tomographOptic Nerve Headsbusiness.industryGlaucomaRetinalMiddle Agedmedicine.diseaseeye diseasesSensory SystemsVisual fieldConfocal scanning laser ophthalmoscopyOphthalmologyEarly Diagnosismedicine.anatomical_structurechemistryAchromatic lensVisual Field TestsFemaleOcular Hypertensionsense organsVisual FieldsbusinessCurrent Eye Research
researchProduct

A European Study of the Performance and Safety of MINIject in Patients With Medically Uncontrolled Open-angle Glaucoma (STAR-II)

2020

Precis In this European study (STAR-II), MINIject, a novel, ab-interno, supraciliary MIGS device, effectively lowered intraocular pressure (IOP) and the need for IOP-lowering medications in patients with primary open-angle glaucoma. Purpose To evaluate the safety and performance of a minimally invasive supraciliary glaucoma drainage device (MINIject DO627, iSTAR Medical SA, Wavre, Belgium) for surgical treatment of primary open angle glaucoma in patients refractory to topical hypotensive medications. Methods In a prospective, interventional, single-arm, multi-center, European study (STAR-II), MINIject was successfully implanted in a standalone procedure in 29 of 31 patients in 8 sites in 3 …

Adultmedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresOpen angle glaucomaGlaucomaOriginal StudiesProsthesis ImplantationTonometry Ocular03 medical and health sciences0302 clinical medicineRefractoryOphthalmologymedicineClinical endpointHumansMinimally Invasive Surgical ProceduresSingle-Blind MethodIn patientEuropean UnionProspective StudiesGlaucoma Drainage ImplantsAdverse effectAntihypertensive AgentsIntraocular PressureAgedAged 80 and overEquipment Safetybusiness.industryIOPMIGSMiddle Agedmedicine.diseaseGlaucoma drainage deviceMINIjecteye diseasesOphthalmologyglaucomaTreatment Outcome030221 ophthalmology & optometryFemalesupraciliarysense organsbusinessGlaucoma Open-Angle030217 neurology & neurosurgeryJournal of Glaucoma
researchProduct