0000000000555858

AUTHOR

Christine S. Zuern

P4730Underweight is associated with unfavourable short- and long-term outcomes after MitraClip therapy: a body mass index derived subgroup analysis of the German Transcatheter Mitral Valve Interventions (

Abstract Background Underweight and obesity represent classical risk factors for patients undergoing cardiac surgery or interventional treatment. The multicentre German Transcatheter Mitral Valve Interventions (TRAMI) registry comprises a large and prospectively enrolled real-world cohort of patients treated by MitraClip implantation. Aims The current analysis examines the impact of underweight, overweight and obesity on intra-hospital, short and long-term outcomes in patients treated by MitraClip therapy. Methods and results From 08/2010 until 07/2013, 799 patients (age 75.3±8.6 years, male gender 60.7%, median logistic EuroSCORE 20% [12; 31], functional mitral regurgitation (MR): 69.3%) w…

research product

Impact of left atrial diameter on outcome in patients undergoing edge-to-edge mitral valve repair: results from the German TRAnscatheter Mitral valve Interventions registry (TRAMI)

Abstract Background Left atrium (LA) dimension is a marker of disease severity and outcome in primary and secondary mitral regurgitation. In transcatheter mitral valve repair LA enlargement might additionally impact on device handling and technical success through an altered anatomy and atrial annular dilatation. Methods Data from the multicenter German transcatheter mitral valve intervention registry “TRAMI” were used to analyse the association of baseline LA diameter by tertiles and efficacy, safety and long-term clinical outcome in patients undergoing edge-to-edge repair with the MitraClip. Results In 520 of 843 patients prospectively enrolled in TRAMI baseline LA diameter were reported …

research product

Safety and efficacy of MitraClip™ therapy in patients with severely impaired left ventricular ejection fraction: results from the German transcatheter mitral valve interventions (TRAMI) registry

Aims The aim of the present study was to assess the safety and efficacy of percutaneous mitral valve repair using the MitraClip™ device in patients with severely reduced systolic left ventricular (LV) function. Methods and results Among 777 MitraClip™ implantations included in the German mitral valve registry, we identified 256 patients suffering from severely reduced LV function [ejection fraction (EF) 50%) and 280 patients presenting with an EF 30–50% prior to MitraClip™ therapy. High procedural success rates, low periprocedural complication rates, and low residual mitral regurgitation grades at discharge were achieved throughout all groups. In-hospital mortality was low and comparable in…

research product