Mechanical behavior of implant assisted removable partial denture for Kennedy class II
Made available in DSpace on 2020-12-12T01:22:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: This study evaluated the mechanical response of a removable partial denture (RPD) in Kennedy Class II according to being associated or not with implants. Material and Methods: Four RPDs were manufactured for a Kennedy Class II: CRPD-Conventional RPD, RPD+ 1M, RPD+2M and RPD+12M, respectively, signifying implant assisted RPDs with the implant installed in the first molar, second molar, and in the first and second molars. The finite element method was used to determine the most damaged support tooth under compressive load (300N, 10s) and strain gauge analysis was used to ev…