0000000000568492

AUTHOR

S. O'brien

Long-term hepatic safety of lomitapide in homozygous familial hypercholesterolaemia

Introduction: Lomitapide is a microsomal triglyceride transfer protein inhibitor for patients with homozygous familial hypercholesterolaemia. Due to its mechanism of action, potential hepatic effects of lomitapide are of clinical interest. This study aimed to determine the long-term hepatic safety of lomitapide. Methods: Data were aggregated from the pivotal phase 3 and extension phase clinical trial with lomitapide (median 5.1 years; serum total bilirubin, transaminases, cytokeratin-18 [CK-18] and enhanced liver fibrosis [ELF] score, fat-soluble vitamins and essential fatty acids), 8-year data from the Lomitapide Observational Worldwide Evaluation Registry (LOWER) and real-world evidence f…

research product

Neutron capture cross section measurements for nuclear astrophyisics at CERN n_TOF

A series of neutron capture cross section measurements of interest to nuclear astrophysics have been recently performed at n_TOF, the neutron spallation source operating at CERN. The low repetition frequency of the proton beam driver, the extremely high instantaneous neutron flux, and the low background conditions in the experimental area are optimal for capture cross section measurements on low-mass or radioactive samples. An overview of the measurements performed during the two experimental campaigns in 2002 and 2003 is presented with special emphasis on the measurement of the capture cross sections of the Os isotopes relevant for the cosmochronology based on the Re/Os clock. http://www.s…

research product

Neutron measurements for advanced nuclear systems: The n_TOF project at CERN

A few years ago, the neutron time-of-flight facility n_TOF was built at CERN to address some of the urgent needs of high-accuracy nuclear data for Accelerator Driven Systems and other advanced nuclear energy systems, as well as for nuclear astrophysics and fundamental nuclear physics. Thanks to the characteristics of the neutron beam, and to state-of-the-art detection and acquisition systems, high quality neutron cross-section data have been obtained for a variety of isotopes, many of which radioactive. Following an important upgrade of the spallation target and of the experimental area, a new measurement campaign has started last year. After a brief review of the most important results obt…

research product

SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study

Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…

research product

Multiband variability studies and novel broadband SED modeling of Mrk 501 in 2009

Astronomy and astrophysics 603, A31 (2017). doi:10.1051/0004-6361/201629540

research product

Early outcomes and complications following cardiac surgery in patients testing positive for coronavirus disease 2019: An international cohort study

The outbreak of severe acute respiratory syndromecoronavirus-2, the cause of coronavirus disease 2019 (COVID-19) in December 2019 represented a global emergency accounting for more than 2.5 million deaths worldwide.1 It has had an unprecedented influence on cardiac surgery internationally, resulting in cautious delivery of surgery and restructuring of services.2 Understanding the influence of COVID-19 on patients after cardiac surgery is based on assumptions from other surgical specialties and single-center studies. The COVIDSurg Collaborative conducted a multicenter cohort study, including 1128 patients, across 235 hospitals, from 24 countries demonstrating perioperative COVID-19 infection…

research product

Production and isobaric separation of 63Ni ions for determination of the 62Ni(n,γ)63Ni reaction cross section at stellar temperatures

research product

Measurement of the n-TOF beam profile with a micromegas detector

A Micromegas detector was used in the neutron Time-Of-Flight (n_TOF) facility at CERN to evaluate the spatial distribution of the neutron beam as a function of its kinetic energy. This was achieved over a large range of neutron energies by using two complementary processes: at low energy by capture of a neutron via the 6Li(n,[alpha])t reaction, and at high energy by elastic scattering of neutrons on gas nuclei (argon+isobutane or helium+isobutane). Data are compared to Monte Carlo simulations and an analytic function fitting the beam profile has been calculated with a sufficient precision to use in neutron capture experiments at the n_TOF facility. http://www.sciencedirect.com/science/artic…

research product

Stellar(n,γ)Cross Section ofNi62

The 62Ni(n,gamma)63Ni(t(1/2)=100+/-2 yr) reaction plays an important role in the control of the flow path of the slow neutron-capture (s) nucleosynthesis process. We have measured for the first time the total cross section of this reaction for a quasi-Maxwellian (kT=25 keV) neutron flux. The measurement was performed by fast-neutron activation, combined with accelerator mass spectrometry to detect directly the 63Ni product nuclei. The experimental value of 28.4+/-2.8 mb, fairly consistent with a recent calculation, affects the calculated net yield of 62Ni itself and the whole distribution of nuclei with 62<A<90 produced by the weak s process in massive stars.

research product

Measurement of the 151Sm n,gamma 152Sm cross section at n_TOF

The 151 Sm(n, γ ) 152 Sm cross section, which is important for the interpretation of the 151 Sm branching as an s -process thermometer, was measured from 1 eV up to 1 MeV at the innovative n_TOF facility at CERN. Based on these data, the Maxwellian-averaged cross section at k T = 30  keV is found to be 3100±160 mb. This value can be used to constrain the thermodynamical conditions in Asymptotic Giant Branch (AGB) stars during He-shell burning.

research product

Broadband Multi-wavelength Properties of M87 during the 2017 Event Horizon Telescope Campaign

Full list of authors: EHT MWL Science Working Group; Algaba, J. C.; Anczarski, J.; Asada, K.; Baloković, M.; Chandra, S.; Cui, Y. -Z.; Falcone, A. D.; Giroletti, M.; Goddi, C.; Hada, K.; Haggard, D.; Jorstad, S.; Kaur, A.; Kawashima, T.; Keating, G.; Kim, J. -Y.; Kino, M.; Komossa, S.; Kravchenko, E. V.; Krichbaum, T. P.; Lee, S. -S.; Lu, R. -S.; Lucchini, M.; Markoff, S.; Neilsen, J.; Nowak, M. A.; Park, J.; Principe, G.; Ramakrishnan, V.; Reynolds, M. T.; Sasada, M.; Savchenko, S. S.; Williamson, K. E.; Event Horizon Telescope Collaboration; Akiyama, Kazunori; Alberdi, Antxon; Alef, Walter; Anantua, Richard; Azulay, Rebecca; Baczko, Anne-Kathrin; Ball, David; Barrett, John; Bintley, Dan; …

research product

Machine learning risk prediction of mortality for patients undergoing surgery with perioperative SARS-CoV-2: the COVIDSurg mortality score

The British journal of surgery 108(11), 1274-1292 (2021). doi:10.1093/bjs/znab183

research product

Measurements of the 90,91,92,94,96 Zr n, gamma cross-sections at n_TOF

Neutron capture cross sections of the 90,91,92,94,96Zr have been measured over the energy range from 1 eV to 1 MeV at the spallation neutron facility n TOF at CERN in 2003. The innovative features of the neutron beam, in particular the high instantaneous flux, the high energy resolution and low background, together with improvements of the neutron sensitivity of the capture detectors make this facility unique for neutron-induced reaction cross section measurements with much improved accuracy. The preliminary results of the Zr measurements show capture resonance strengths generally smaller than in previous measurements. Peer Reviewed

research product