0000000000574027

AUTHOR

J. Baker

showing 9 related works from this author

Measurement of the double-βdecay half-life ofNd150and search for neutrinoless decay modes with the NEMO-3 detector

2009

The half-life for double-{beta} decay of {sup 150}Nd has been measured by the NEMO-3 experiment at the Modane Underground Laboratory. Using 924.7 days of data recorded with 36.55 g of {sup 150}Nd, we measured the half-life for 2{nu}{beta}{beta} decay to be T{sub 1/2}{sup 2{nu}}=(9.11{sub -0.22}{sup +0.25}(stat.){+-}0.63(syst.))x10{sup 18} yr. The observed limit on the half-life for neutrinoless double-{beta} decay is found to be T{sub 1/2}{sup 0{nu}}>1.8x10{sup 22} yr at 90% confidence level. This translates into a limit on the effective Majorana neutrino mass of <4.0-6.3 eV if the nuclear deformation is taken into account. We also set limits on models involving Majoron emission, right-hand…

PhysicsNuclear and High Energy PhysicsParticle physics010308 nuclear & particles physicsElementary particle7. Clean energy01 natural sciencesBeta decayNuclear physicsMAJORANADouble beta decay0103 physical sciencesNeutrino010306 general physicsRadioactive decayMajoronLeptonPhysical Review C
researchProduct

Measurement of the background in the NEMO 3 double beta decay experiment

2009

In the double beta decay experiment NEMO 3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO 3 to evaluate the backgrounds resulting from most if not all possible origins. It also illustrates the power of the combined tracking-calorimetry technique used in the experiment.

Nuclear and High Energy Physicscongenital hereditary and neonatal diseases and abnormalitiesSignal regionchemistry.chemical_elementFOS: Physical sciencesRadon[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesNuclear physicsNEMODouble beta decay0103 physical sciencesNeutrino Ettore Majorana ObservatoryNuclear Experiment (nucl-ex)010306 general physicsskin and connective tissue diseasesLow radioactivityInstrumentationNuclear ExperimentPhysics010308 nuclear & particles physicsDetectorDouble beta decayPower (physics)BackgroundchemistryRadon
researchProduct

Results of the search for neutrinoless double-βdecay inMo100with the NEMO-3 experiment

2015

The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $\beta$ ($0\nu\beta\beta$) decay. We report final results of a search for $0\nu\beta\beta$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected background in the $0\nu\beta\beta$ signal region and find no evidence of $0\nu\beta\beta$ decays in the data. The level of observed background in the $0\nu\beta\beta$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg, and no events are obs…

PhysicsNuclear and High Energy PhysicsParticle physics010308 nuclear & particles physicsSignal region01 natural sciencesBeta decayLower limitNuclear physicsMAJORANADouble beta decay0103 physical sciencesUnderground laboratoryBeta (velocity)Neutrino010306 general physicsPhysical Review D
researchProduct

Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors

2010

We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.

Nuclear and High Energy PhysicsPhotomultiplierTechnologyPhysics - Instrumentation and DetectorsPhotonPhysics::Instrumentation and DetectorsCODEFOS: Physical sciencesScintillator01 natural sciencesHigh Energy Physics - ExperimentPhysics Particles & FieldsNuclear physicsHigh Energy Physics - Experiment (hep-ex)Photomultiplier0202 Atomic Molecular Nuclear Particle And Plasma PhysicsDouble beta decay0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]CalibrationPlastic scintillators[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsNuclear Science & TechnologyInstrumentationInstruments & InstrumentationScintillationphysics.ins-detPhysicsScintillationScience & Technology010308 nuclear & particles physicshep-exPhysicsMO-100DetectorInstrumentation and Detectors (physics.ins-det)Double beta decayNuclear & Particles PhysicsCalorimeterPhysics NuclearPhysical SciencesGEANT 4DOUBLE-BETA DECAYOptical photon transport
researchProduct

Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

2010

Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.

PhysicsNuclear and High Energy PhysicsIsotope010308 nuclear & particles physicsDetectorFOS: Physical sciencesHalf-lifeElectron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesNuclear physicsRadioactivityAngular distributionDouble beta decay0103 physical sciencesNuclear Experiment (nucl-ex)Neutrino010306 general physicsNuclear ExperimentEnergy (signal processing)
researchProduct

Measurement of theββDecay Half-Life ofTe130with the NEMO-3 Detector

2011

This Letter reports results from the NEMO-3 experiment based on an exposure of 1275 days with 661g of 130Te in the form of enriched and natural tellurium foils. With this data set the double beta decay rate of 130Te is found to be non-zero with a significance of 7.7 standard deviations and the half-life is measured to be T1/2 = (7.0 +/- 0.9(stat) +/- 1.1(syst)) x 10^{20} yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.

PhysicsIsotope010308 nuclear & particles physicsStable isotope ratioGeneral Physics and AstronomyHalf-lifechemistry.chemical_element01 natural sciencesBeta decayNuclear physicschemistryDouble beta decay0103 physical sciencesNeutrino Ettore Majorana Observatory010306 general physicsTelluriumRadioactive decayPhysical Review Letters
researchProduct

Search for neutrinoless double-beta decay ofMo100with the NEMO-3 detector

2014

We report the results of a search for the neutrinoless double-$\beta$ decay (0$\nu\beta\beta$) of $^{100}$Mo, using the NEMO-3 detector to reconstruct the full topology of the final state events. With an exposure of 34.7 kg.y, no evidence for the 0$\nu\beta\beta$ signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of $T_{1/2}(0\nu\beta\beta)>1.1 \times 10^{24}$ years (90% C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of $ < 0.3-0.8$ eV (90% C.L.). Constraints on other lepton number violating mechanisms of 0$…

PhysicsNuclear and High Energy PhysicsParticle physics010308 nuclear & particles physicsElectron01 natural sciencesBeta decayLepton numberNuclear physicsMAJORANADouble beta decay0103 physical sciencesBeta (velocity)Neutrino010306 general physicsEnergy (signal processing)Physical Review D
researchProduct

SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study

2021

Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…

MaleCOVID-19 Vaccinesafe surgery; vaccination modelling; COVID-19Vascular damage Radboud Institute for Health Sciences [Radboudumc 16]MULTICENTERComorbidity030230 surgery0302 clinical medicinephase 3 clinical trial (topic)Case fatality rateProspective StudiesSARS-CoV-2 Vaccination Safe surgeryCOVID-19/epidemiologySARS-CoV-2 ; vaccination ; safe surgeryeducation.field_of_studycase fatality rateVaccinationVaccinationAdolescent; Adult; Aged; COVID-19; COVID-19 Vaccines; Comorbidity; Elective Surgical Procedures; Female; Humans; Male; Middle Aged; Postoperative Complications; Preoperative Period; Prospective Studies; SARS-CoV-2; Vaccination; Young Adulthealth care policyElective Surgical Procedures030220 oncology & carcinogenesisvaccination modellingPreoperative PeriodCOVID-19; SARS-CoV-2; cancer; vaccination; outcome; mortality; infection; modellingCohort studyprospective studyHumanmedicine.medical_specialtyArticle03 medical and health sciencesSARS-CoV-2 vaccinationSDG 3 - Good Health and Well-beingCOVID-19 Vaccines/pharmacologyHumansVaccination/methodsElective surgeryeducationAgedScience & TechnologyElective Surgical Procedureadult; aged; Article; cancer grading; cancer surgery; case fatality rate; computer assisted tomography; elective surgery; female; follow up; health care policy; human; incidence; infection rate; infection risk; major clinical study; male; middle aged; mortality; outcome assessment; phase 3 clinical trial (topic); preoperative care; prospective study; sensitivity analysis; seroprevalence; Severe acute respiratory syndrome coronavirus 2; vaccination; young adult; COVID-19; COVID-19 Vaccines; Comorbidity; Elective Surgical Procedures; Postoperative Complications; Preoperative Period; SARS-CoV-2; Vaccination; surgery.Cura preoperatòriamajor clinical studymortalityinfectionProspective StudieincidenceSurgeryHuman medicinePostoperative Complication610 Medizin und GesundheitAcademicSubjects/MED00910Settore MED/18 - CHIRURGIA GENERALESettore MED/29 - CHIRURGIA MAXILLOFACCIALEcomputer assisted tomographyESTUDOS PROSPECTIVOSsurgerysafe surgeryPostoperative Complicationssensitivity analysisSevere acute respiratory syndrome coronavirus 2preoperative careVacunacióProspective cohort studyseroprevalenceIncidence (epidemiology)covidElective Surgical Procedures/methodsMiddle Agedcancer gradingCOVID vaccinationoutcome/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_beingSARS-CoV-2; vaccination; surgeryOriginal ArticleFemalecancer surgeryAcademicSubjects/MED00010Life Sciences & BiomedicineAdultCOVID-19 VaccinesAdolescentinternational prospective cohort studyPostoperative Complications/prevention & controlPopulationinfection rateSARS-CoV-2/immunologyNOmodellingYoung Adultmedicinefollow upcancerddc:610infection riskoutcome assessmentLS7_4business.industrySARS-CoV-2Number needed to vaccinatePreoperative careCOVID-193126 Surgery anesthesiology intensive care radiologySettore MED/18Reconstructive and regenerative medicine Radboud Institute for Health Sciences [Radboudumc 10]elective surgeryEmergency medicinebusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyThe British Journal of Surgery
researchProduct

The transient gravitational-wave sky

2013

Classical and Quantum Gravity, 30, id. 193002 (2013)
researchProduct