0000000000613886

AUTHOR

Kashif Shaikh

0000-0001-8468-4996

showing 2 related works from this author

Evaluating the quality of implantation of percutaneous ventricular restoration device (Parachute®) by cardiac computed tomography

2016

Background The Parachute is a novel percutaneously implanted ventricular partitioning device (VPD) that has emerged as a safe and feasible treatment option for patients with heart failure following anterior wall myocardial infarction. VPD efficacy is likely dependent on optimal device placement, but to date there are no published data examining the effect of device positioning on patient outcomes. Methods and results We retrospectively identified 32 patients successfully implanted with the Parachute device, all of whom underwent cardiac computed tomography (CCT) at baseline and after 6 months of follow-up. Patients were divided into two groups based on self-reported improvement in New York …

medicine.medical_specialtyPercutaneousbusiness.industrymedicine.medical_treatmentRetrospective cohort studyGeneral MedicineStroke volume030204 cardiovascular system & hematologymedicine.diseaseSurgery03 medical and health sciences0302 clinical medicineHeart failuremedicineRadiology Nuclear Medicine and imagingAnterior Wall Myocardial Infarction030212 general & internal medicineImplantCardiology and Cardiovascular MedicinebusinessVentricular remodelingCardiac catheterizationCatheterization and Cardiovascular Interventions
researchProduct

Cardiac computed tomography assessment of the near term impact of percutaneous ventricular restoration therapy (parachute®) on mitral valve geometry

2015

Objectives The aim of current study is to assess the near term impact of percutaneous ventricular restoration therapy (PVR), Parachute® on mitral valve (MV) geometry by cardiac computed tomography (CCT). Background Recent data demonstrates the feasibility of PVR for treatment of post anterior myocardial infarction (MI) heart failure. Little is known, however, about the interaction of the device and left ventricular structures, particularly the MV apparatus. Methods This is a retrospective Core Laboratory analysis of Parachute Trials’ CCT data. Patients with paired (before and after Parachute implant) CCT acquisitions were included into analysis. MV geometric parameters were measured. Result…

medicine.medical_specialtyPercutaneousCardiac computed tomographybusiness.industryDiastoleAnterior myocardial infarctionGeometryGeneral Medicine030204 cardiovascular system & hematologymedicine.disease03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureHeart failureMitral valveInternal medicinemedicineCardiologyRadiology Nuclear Medicine and imaging030212 general & internal medicineImplantCore laboratoryCardiology and Cardiovascular MedicinebusinessCatheterization and Cardiovascular Interventions
researchProduct