0000000000637758

AUTHOR

F. Pompei

showing 5 related works from this author

Performance of prototypes for the ALICE electromagnetic calorimeter

2009

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A $4\times4$ array of final design modules showed an energy resolution of about 11% /$\sqrt{E(\mathrm{GeV})}$ $\oplus$ 1.7 % with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5 mm $\oplus$ 5.3 mm /$\sqrt{E \mathrm{(GeV)}}$. For an electron identification efficiency of 90% a hadron rejection factor of $>600$ was obtained.

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsHadronFOS: Physical sciencesElectron7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex][PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Physics - Instrumentation and Detectors; Physics - Instrumentation and Detectors; High Energy Physics - ExperimentDetectors and Experimental Techniques010306 general physicsNuclear ExperimentInstrumentationImage resolutionPhysicsRange (particle radiation)Large Hadron Collider010308 nuclear & particles physicsLinearityInstrumentation and Detectors (physics.ins-det)CalorimeterHigh Energy Physics::ExperimentALICE (propellant)
researchProduct

Factors associated with first- versus second-generation long-acting antipsychotics prescribed under ordinary clinical practice in Italy

2018

Background For many years, long-acting intramuscular (LAI) antipsychotics have been prescribed predominantly to chronic and severe patients, as a last resort when other treatments failed. Recently, a broader and earlier use of LAIs, particularly second-generation LAIs, has been emphasized. To date, few studies attempted to frame how this change in prescribing took place in real-world practice. Therefore, this study aimed to describe the clinical features of patients prescribed with LAIs, and to explore possible prescribing differences between first- and second-generations LAIs under ordinary clinical practice in Italy. Methods The STAR Network "Depot" Study is an observational, longitudinal…

Genetics and Molecular Biology (all)MalePediatricsEuropean PeopleBipolar DisorderCross-sectional studyEconomicsEpidemiologymedicine.medical_treatmentassessmentviruseslcsh:MedicineSocial SciencesLongitudinal StudieBiochemistryPrescriptionGeographical locations0302 clinical medicineMathematical and Statistical TechniquesBiochemistry Genetics and Molecular Biology (all); Agricultural and Biological Sciences (all)immune system diseasesEpidemiologyMedicine and Health Scienceslong-acting intramuscular (LAI) antipsychotics; clinical practice; assessment; second-generation antipsychotic (SGA) LAIsAntipsychoticsEthnicitiesLongitudinal Studieslcsh:ScienceMultidisciplinaryvirus diseasesDrugsMiddle Agedclinical practiceItalian PeopleEuropePrescriptionsItalyPhysical SciencesAripiprazoleFemaleBivariate AnalysisStatistics (Mathematics)medicine.drugHumanResearch ArticleAntipsychotic AgentsEmploymentAdultmedicine.medical_specialtyAdolescentResearch and Analysis Methods03 medical and health sciencesMental Health and PsychiatrymedicineHumansPaliperidoneBipolar disorderEuropean UnionStatistical MethodsAntipsychoticCross-Sectional StudiePharmacologyRisperidoneBiochemistry Genetics and Molecular Biology (all)business.industryMood Disorderslcsh:Rmedicine.disease030227 psychiatryAntipsychotic AgentCross-Sectional StudiesAgricultural and Biological Sciences (all)Labor EconomicsMultivariate AnalysisSchizophreniaObservational studylcsh:QPopulation Groupingslong-acting intramuscular (LAI) antipsychoticsPeople and placesbusiness030217 neurology & neurosurgerysecond-generation antipsychotic (SGA) LAIsMathematicsPLoS ONE
researchProduct

Comparing Long-Acting Antipsychotic Discontinuation Rates Under Ordinary Clinical Circumstances: A Survival Analysis from an Observational, Pragmatic…

2021

Background Recent guidelines suggested a wider use of long-acting injectable antipsychotics (LAI) than previously, but naturalistic data on the consequences of LAI use in terms of discontinuation rates and associated factors are still sparse, making it hard for clinicians to be informed on plausible treatment courses. Objective Our objective was to assess, under real-world clinical circumstances, LAI discontinuation rates over a period of 12 months after a first prescription, reasons for discontinuation, and associated factors. Methods The STAR Network ‘Depot Study’ was a naturalistic, multicentre, observational prospective study that enrolled subjects initiating a LAI without restrictions …

MalePediatricsrespectively)0302 clinical medicineDelayed-Action PreparationBrief Psychiatric Rating ScalePharmacology (medical)he STAR Network ‘Depot Study’ prospectively followed 394 subjects initiating treatment with long-acting injections (LAIs) of antipsychotics under naturalistic conditions for 12 months. LAI discontinuation was frequent in everyday clinical practice in ItalyOriginal Research ArticleProspective StudiesProspective cohort studytreatmentMental DisordersHazard ratiowhereas more than half of participants initiating risperidone LAI and olanzapine LAI discontinued during the 12 months of follow-up (51.4 and 62.5%Psychiatric Status Rating ScaleMiddle Agedside efectsPsychiatry and Mental healthItalyMental DisorderFemalehe STAR Network ‘Depot Study’ prospectively followed 394 subjects initiating treatment with long-acting injections (LAIs) of antipsychotics under naturalistic conditions for 12 months. LAI discontinuation was frequent in everyday clinical practice in Italy occurring in almost 40% of the entire sample; side efects participant refusal to continue LAIs and LAIs no longer being required were the most frequently reported reasons for discontinuation. Paliperidone LAI and aripiprazole LAI were the least discontinued medications (33.9 and 35.4% respectively) whereas more than half of participants initiating risperidone LAI and olanzapine LAI discontinued during the 12 months of follow-up (51.4 and 62.5% respectively). In multivariate analysis being prescribed olanzapine LAI and poor medication adherence at baseline were signifcantly associated with higher discontinuation risk.HumanAntipsychotic Agentsmedicine.drugPsychopathologyAdultmedicine.medical_specialtyDiscontinuationFollow-Up StudieMedication Adherence03 medical and health sciencesmedicineHumansPaliperidoneAdverse effectSettore MED/25 - Psichiatriadiscontinuation ratesPsychiatric Status Rating Scalesrespectively). In multivariate analysisbusiness.industryLong-Acting Antipsychoticlong-acting injectable antipsychoticsSurvival AnalysisConfidence intervalparticipant refusal to continue LAIs and LAIs no longer being required were the most frequently reported reasons for discontinuation. Paliperidone LAI and aripiprazole LAI were the least discontinued medications (33.9 and 35.4%030227 psychiatryDiscontinuationProspective StudieAntipsychotic Agentoccurring in almost 40% of the entire sampleDelayed-Action PreparationsNeurology (clinical)business030217 neurology & neurosurgerybeing prescribed olanzapine LAI and poor medication adherence at baseline were signifcantly associated with higher discontinuation riskFollow-Up Studies
researchProduct

The ALICE experiment at the CERN LHC

2008

Journal of Instrumentation 3(08), S08002 (2008). doi:10.1088/1748-0221/3/08/S08002

visible and IR photonsLiquid detectorshigh energyPhotonPhysics::Instrumentation and DetectorsTransition radiation detectorsTiming detectors01 natural sciencesOverall mechanics designParticle identificationSoftware architecturesParticle identification methodsGaseous detectorscluster findingDetector cooling and thermo-stabilizationDetector groundingParticle tracking detectors[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Special cablesDetector alignment and calibration methodsDetectors and Experimental TechniquesNuclear ExperimentVoltage distributions.Photon detectors for UVInstrumentationMathematical PhysicsQuantum chromodynamicsPhysicsLarge Hadron ColliderSpectrometersPhysicsDetectorcalibration and fitting methodsTransition radiation detectorScintillatorsData processing methodsAnalysis and statistical methodsData reduction methodsParticle physicsCherenkov and transition radiationTime projection chambers610dE/dx detectorsNuclear physicsCalorimetersPattern recognitionGamma detectors0103 physical sciencesddc:610Solid state detectors010306 general physicsMuonInstrumentation for heavy-ion acceleratorsSpectrometerLarge detector systems for particle and astroparticle physics010308 nuclear & particles physicsCERN; LHC; ALICE; heavy ion; QGPCherenkov detectorsComputingVoltage distributionsManufacturingscintillation and light emission processesanalysis and statistical methods; calorimeters; cherenkov and transition radiation; cherenkov detectors; computing; data processing methods; data reduction methods; de/dx detectors; detector alignment and calibration methods; detector cooling and thermo-stabilization; detector design and construction technologies and materials; detector grounding; gamma detectors; gaseous detectors; instrumentation for heavy-ion accelerators; instrumentation for particle accelerators and storage rings - high energy; large detector systems for particle and astroparticle physics; liquid detectors; manufacturing; overall mechanics design; particle identification methods; particle tracking detectors; pattern recognition; cluster finding; calibration and fitting methods; photon detectors for uv; visible and ir photons; scintillators; scintillation and light emission processes; simulation methods and programs; software architectures; solid state detectors; special cables; spectrometers; time projection chambers; timing detectors; transition radiation detectors; voltage distributionsInstrumentation for particle accelerators and storage ringsInstrumentation; Mathematical PhysicsHigh Energy Physics::ExperimentSimulation methods and programsDetector design and construction technologies and materials
researchProduct

The upgrade of the ALICE TPC with GEMs and continuous readout

2020

Journal of Instrumentation 16(03), P03022 (2021). doi:10.1088/1748-0221/16/03/P03022

Physics - Instrumentation and DetectorsComputer sciencePhysics::Instrumentation and DetectorsFOS: Physical sciences61001 natural sciences114 Physical sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine0103 physical sciencesMicropattern gaseous detectors (MSGC GEM THGEM RETHGEM MHSP MICROPIC MICROMEGAS InGrid etc)Electronicsddc:610Detectors and Experimental TechniquesInstrumentationphysics.ins-detMathematical PhysicsCMOS readout of gaseous detectorsLarge Hadron Collider010308 nuclear & particles physicsbusiness.industryDetectorTime projection Chambers (TPC)Readout electronicsInstrumentation and Detectors (physics.ins-det)ChipUpgradeGaseous imaging and tracking detectorsGas electron multiplierALICE (propellant)businessComputer hardware
researchProduct