The Measurement of Enzyme Activities in the Resting Human Polymorphonuclear Leukocyte — Critical Estimate of a Method
As a system for study, the isolated human polymorphonuclear leukocyte combines the advantages of a quasi-non-invasive preparation with a nearly complete complement of enzymes of carbohydrate and energy metabolism. However, small sample volumes and, in some cases, very low enzyme activities make high demands on sample processing, storage, and performance of continuous measurements, if the enzyme activities are to be measured with acceptable reproducibility. In the presented study several aspects of homogenization, storage, and continuous measurement were scrutinized, to identify critical steps and consider ways of optimizing the method. Polymorphonuclear leukocytes were separated from the bl…