0000000000650622

AUTHOR

Konstantinos P. Donas

showing 10 related works from this author

A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…

2012

Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …

Malemedicine.medical_specialtyPercutaneousTime Factorsmedicine.medical_treatmentAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive Diseases610 Medicine & healthConstriction PathologicAnastomosisProsthesis DesignAortographyIliac Artery2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPostoperative Complicationsmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingVascular CalcificationAgedAortabusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresSuture TechniquesStentExternal iliac arteryGeneral MedicineMiddle Agedmedicine.diseaseConstrictionSurgeryBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgeryStenosisTreatment OutcomeBypass surgerySurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computed
researchProduct

Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry

2018

Abstract Objective The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry. Methods The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), n…

MaleRegistrieTime FactorsEndoleakmedicine.medical_treatmentComorbidity030204 cardiovascular system & hematology030230 surgeryEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRisk FactorsRetrospective StudieOcclusionOdds RatioStentRegistriesMultivariate AnalysiPolytetrafluoroethyleneAged 80 and overEndovascular ProceduresHazard ratioGraft Occlusion VascularEuropeBlood Vessel ProsthesiTreatment OutcomeCardiothoracic surgeryStentsFemaleCardiology and Cardiovascular MedicineSTENT GRAFT; CHIMENY GRAFT; CHIMNEY TECHINQUEHumanUnited Statemedicine.medical_specialtyHospitals Low-VolumeTime FactorPolyestersPolyesterProsthesis DesignDisease-Free Survival03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesisAlloysmedicineHumansProportional Hazards ModelsRetrospective StudiesAgedEndovascular ProcedureAortic Aneurysm Thoracicbusiness.industryRisk FactorStentOdds ratiomedicine.diseaseStainless SteelUnited StatesBlood Vessel ProsthesisSurgeryMultivariate AnalysisAlloyProportional Hazards ModelSurgerybusinessHospitals High-VolumeAortic Aneurysm Abdominal
researchProduct

IF01. Collected Worldwide Experience From the PERICLES Registry With the Use of Chimney Grafts in the Treatment of Type I Endoleaks After Previous En…

2017

medicine.medical_specialtyPERICLESbusiness.industrymedicine.medical_treatmentPERICLES; chimney; endoleakendoleakSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairSurgeryMedicineSurgeryChimneyRadiologyCardiology and Cardiovascular MedicinebusinesschimneyJournal of Vascular Surgery
researchProduct

Incidence and prognostic factors related to major adverse cerebrovascular events in patients with complex aortic diseases treated by the chimney tech…

2018

Abstract Objective Endovascular aneurysm repair (EVAR) with the chimney technique (ch-EVAR) has been used for the treatment of aortic aneurysms as an alternative approach to fenestrated endografting or open repair. Nonetheless, the need for an upper extremity arterial access may contribute to a higher risk for periprocedural cerebrovascular events. This study reports on the perioperative cerebral and major adverse cardiac and cerebrovascular events (MACCE) after ch-EVAR. Methods The PERICLES registry (PERformance of the chImney technique for the treatment of Complex aortic pathoLogiES) is an international, retrospective multicenter study evaluating the performance of ch-EVAR for the treatme…

RegistrieMaleTime Factorsmedicine.medical_treatment030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repair0302 clinical medicineRetrospective StudieRisk FactorsCause of DeathCarotid artery diseaseOdds RatioRegistries030212 general & internal medicineMultivariate AnalysiStrokeCause of deathAged 80 and overIncidenceEndovascular ProceduresAtrial fibrillationchimney technique; stroke; aortic archMiddle AgedStrokeHeart DiseaseTreatment OutcomeIschemic Attack TransientCerebrovascular DisorderCardiologyFemaleCardiology and Cardiovascular MedicineHumanAdultmedicine.medical_specialtyAcute coronary syndromeLogistic ModelTime FactorHeart DiseasesOperative TimeAortic DiseasesBlood Vessel Prosthesis Implantation03 medical and health sciencesInternal medicinemedicineHumanscardiovascular diseasesAgedRetrospective StudiesEndovascular ProcedureChi-Square Distributionbusiness.industryRisk FactorOdds ratioPerioperativeAortic Diseasemedicine.diseaseSurgeryCerebrovascular DisordersLogistic ModelsMultivariate AnalysisSurgerybusiness
researchProduct

Results of chimney endovascular aneurysm repair as used in the PERICLES Registry to treat patients with suprarenal aortic pathologies

2020

Background: The prevailing evidence calls for using chimney/snorkel endovascular repair (ch-EVAR) with one or two chimney grafts. No studies up to now focus on its applicability and results for the treatment of suprarenal aortic pathologies (SRAP). Hence, we evaluated the clinical and radiologic results of ch-EVAR treatment for SRAP placing three or more chimney grafts within the PERICLES Registry. Methods: Data from 517 patients suffering complex aortic pathologies treated by ch-EVAR between 2008 and 2014 at 13 European and U.S. centers were retrospectively reviewed and analyzed. Results: Sixty-seven ch-EVAR-treated patients (12.9% of the entire PERICLES cohort) presented SRAP (83.5% elect…

MaleTime Factorsmedicine.medical_treatmentTechnical success030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolarePostoperative ComplicationsRenal Artery0302 clinical medicineRisk FactorsSuperior mesenteric arteryChimneyRegistries030212 general & internal medicineSuperior mesenteric arteryAged 80 and overTriple chimney EVARIncidence (epidemiology)Endovascular ProceduresChimney graftEuropeSuprarenal aneurysmsTreatment OutcomeCohortFemaleStentsCardiology and Cardiovascular Medicinemedicine.medical_specialtyAortic DiseasesProsthesis DesignBlood Vessel Prosthesis Implantation03 medical and health sciencesAneurysmMesenteric Artery Superiormedicine.arterymedicineHumansComplex aneurysmAgedRetrospective StudiesSuprarenal aneurysmbusiness.industryComplex aneurysms; Multiple chimney EVAR; Superior mesenteric artery; Suprarenal aneurysms; Triple chimney EVARmedicine.diseaseMultiple chimney EVARUnited StatesBlood Vessel ProsthesisSurgerySurgerybusinessComplex aneurysms
researchProduct

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct

RS12. Sustained Late Branch Patency and Low Incidence of Persistent Type Ia Endoleaks Following Snorkel/chimney EVAR Shown in the Updated PERICLES Re…

2016

medicine.medical_specialtybusiness.industryIncidence (epidemiology)030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareSurgery03 medical and health sciences0302 clinical medicineEndoleak; snorkel; chimney; PERICLEMedicineSurgeryChimney030212 general & internal medicineCardiology and Cardiovascular Medicinebusiness
researchProduct

Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.

2012

Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …

Malemedicine.medical_specialtyTime FactorsEndoleakmedicine.medical_treatmentEVAR aneurysm chimney periscopesAortic Diseases610 Medicine & healthKaplan-Meier EstimateRevascularizationBalloonProsthesis DesignSettore MED/22 - Chirurgia VascolareAortographyRisk Assessment2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPredictive Value of TestsRisk FactorsAngioplastyGermanymedicineHumansVascular PatencyComputed tomography angiographyAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryStentPerioperativemedicine.disease10020 Clinic for Cardiac Surgery2746 SurgerySurgeryBlood Vessel ProsthesisStenosisTreatment OutcomeCuffSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonSwitzerlandJournal of vascular surgery
researchProduct

Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results

2018

Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…

MaleTime Factorsabdominal aortic aneurysm; chimney graft; chimney technique; endoleak; endovascular aneurysm repair; juxtarenal aortic aneurysm; parallel graft; pararenal aortic aneurysm; periscope graft; snorkel graftmedicine.medical_treatmentJuxtarenal aortic aneurysm030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repair0302 clinical medicineRisk FactorsRetrospective analysisChimneyRegistries030212 general & internal medicineAged 80 and overEndovascular ProceduresChimney graftAbdominal aortic aneurysmEuropeTreatment Outcomesnorkel graftFemaleStentsjuxtarenal aortic aneurysmCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyparallel graftendoleakperiscope graftProsthesis Designpararenal aortic aneurysmBlood Vessel Prosthesis Implantation03 medical and health sciencesabdominal aortic aneurysmchimney techniquemedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industrychimney graftmedicine.diseaseUnited StatesBlood Vessel ProsthesisSurgerySurgerybusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

Classification of Chimney EVAR-Related Endoleaks: Insights from the PERICLES Registry

2017

Juxtarenal aortic aneurysms (JAAs) pose significant challenges for endovascular aneurysm repair (EVAR). A short or absent infrarenal neck typically excludes standard EVAR as a viable or reasonable treatment option. In this context, the use of chimney grafts (chEVAR) is gaining in popularity and applicability. These grafts are designed to course in the aortic lumen outside the main stent-graft to maintain normal perfusion to the involved target branches. As such, they may represent a promising and less resource-intensive option for management of JAAs. However, this technical strategy is not without challenges of its own, particularly the inevitable creation of “gutters” that result from the …

medicine.medical_specialtyRadiology Nuclear Medicine and Imagingabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graftendoleak610 Medicine & health030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineabdominal aortic aneurysmchimney techniqueNuclear Medicine and Imagingmedicine2741 Radiology Nuclear Medicine and ImagingChimney030212 general & internal medicinestent-graftbusiness.industryChimney graftchimney graftendograftmedicine.diseaseAbdominal aortic aneurysmSurgery10020 Clinic for Cardiac Surgery2746 SurgerygraftSurgerystentRadiologybusinessCardiology and Cardiovascular Medicineabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graft; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
researchProduct