0000000000661367

AUTHOR

Hussein Amhaz

showing 2 related works from this author

Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

2007

To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…

MaleRefractive errormedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaEye diseasemedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensResidualVision disorderPostoperative ComplicationsApodizationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansProspective StudiesAgedLenses IntraocularMonocularbusiness.industryMiddle Agedmedicine.diseaseRefractive Errorseye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Visual function after implantation of an aspheric bifocal intraocular lens.

2009

Purpose To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m 2 ) and mesopic (3.0 cd/m 2 ) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered. Results Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, −0.064 ± 0.049…

Malemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesMedicineContrast (vision)HumansProspective StudiesDioptremedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)Middle Agedeye diseasesSensory SystemsOphthalmologyPatient SatisfactionVisual DisturbanceOptometrySurgeryFemaleSpatial frequencybusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct