0000000000666959

AUTHOR

Michael Magro

showing 2 related works from this author

TCT-350 Safety and Performance of the Resorbable Magnesium Scaffold, Magmaris in a Real World Setting - First 400 Subjects at 12-month Follow-up of t…

2018

The aim of this registry is to investigate the clinical performance and long-term safety of the Resorbable Magnesium Scaffold (Magmaris) (BIOTRONIK AG, Buelach, Switzerland) in a real-world setting. Up to 2,054 subjects in up to 120 clinical sites in Europe, Asia, and Asia-Pacific countries will

Scaffoldmedicine.medical_specialtybusiness.industry0206 medical engineeringClinical performance02 engineering and technology030204 cardiovascular system & hematology020601 biomedical engineering03 medical and health sciences0302 clinical medicineInternal medicineCohortMedicineCardiology and Cardiovascular MedicinebusinessMonth follow upJournal of the American College of Cardiology
researchProduct

Prognostic Value of Microvascular Obstruction and Infarct Size, as Measured by CMR in STEMI Patients

2014

The aim of this study was to evaluate the value of microvascular obstruction (MO) and infarct size as a percentage of left ventricular mass (15%LV), as measured by contrast-enhanced cardiac magnetic resonance, in predicting major cardiovascular adverse events (MACE) at 2 years in patients with ST-segment elevation myocardial infarction reperfused by primary percutaneous coronary intervention. Individual data from 1,025 patients were entered into the pooled analysis. MO was associated with the occurrence of MACE, defined as a composite of cardiac death, congestive heart failure, and myocardial re-infarction (adjusted hazard ratio: 3.74; 95% confidence interval: 2.21 to 6.34). IS% LV >= 25% w…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentmicrovascular obstructionHeart VentriclesMyocardial Infarction[SDV.IB.MN]Life Sciences [q-bio]/Bioengineering/Nuclear medicineRisk Assessmentcardiac magnetic resonance[ SDV.IB.MN ] Life Sciences [q-bio]/Bioengineering/Nuclear medicinePercutaneous Coronary InterventionPredictive Value of TestsRecurrenceRisk FactorsInternal medicineCoronary CirculationMedicineinfarct sizeHumansRadiology Nuclear Medicine and imagingMyocardial infarctioncardiovascular diseasesAdverse effectComputingMilieux_MISCELLANEOUSAgedHeart Failurebusiness.industryMicrocirculationMyocardiumHazard ratioPercutaneous coronary interventionMiddle Agedmedicine.diseaseMagnetic Resonance ImagingConfidence intervalTreatment OutcomeRadiology Nuclear Medicine and imagingHeart failureNo reflow phenomenonCardiologyNo-Reflow PhenomenonFemaleprognosisCardiology and Cardiovascular MedicinebusinessMaceJACC. Cardiovascular imaging
researchProduct