0000000000681781

AUTHOR

Y. Vander Heyden

showing 2 related works from this author

Quantitative structure-retention and retention-activity relationships of beta-blocking agents by micellar liquid chromatography.

2001

Abstract Sixteen β-blocking agents (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol and timolol) showing a large range of hydrophobicity (octanol–water partition coefficients, log P between −0.026 and 2.81) were subjected to micellar liquid chromatography with sodium dodecyl sulfate as micelle forming agent, and n-propanol as organic modifier. The correlation between log P and the retention factor extrapolated to a mobile phase free of micelles and organic modifier was investigated. The use of an interpolated retention factor or the retention factor for specific individual exp…

ChromatographyChemistryOrganic ChemistryAdrenergic beta-AntagonistsQuantitative Structure-Activity RelationshipGeneral MedicineBiochemistryMicelleAcebutololMicellar electrokinetic chromatographyAnalytical ChemistryPartition coefficientchemistry.chemical_compoundMicellar liquid chromatographyOxprenololmedicineAlprenololSodium dodecyl sulfateMicellescirculatory and respiratory physiologymedicine.drugChromatography LiquidJournal of chromatography. A
researchProduct

Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals

2005

Several interlinked algorithms for peak deconvolution by non-linear regression are presented. These procedures, together with the peak detection methods outlined in Part I, have allowed the implementation of an automatic method able to process multi-overlapped signals, requiring little user interaction. A criterion based on the evaluation of the multivariate selectivity of the chromatographic signal is used to auto-select the most efficient deconvolution procedure for each chromatographic situation. In this way, non-optimal local solutions are avoided in cases of high overlap, and short computation times are obtained in situations of high resolution. A new algorithm, fitting both the origin…

Blind deconvolutionPolynomialPropagation of uncertaintyChromatographySeries (mathematics)business.industryNoise (signal processing)ChemistryGaussianOrganic ChemistryGeneral MedicineAutomationBiochemistryPeak detectionAnalytical Chemistrysymbols.namesakeLocal optimumApproximation errorsymbolsDeconvolutionbusinessAlgorithmSmoothingSecond derivativeJournal of Chromatography A
researchProduct