0000000000704529

AUTHOR

Ana Señaris

showing 2 related works from this author

Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.

2007

To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…

AdultMaleVisual acuitygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularMedicineContrast (vision)HumansProspective Studiesmedia_commonAgedQuality Indicators Health CareAged 80 and overLenses IntraocularVision BinocularMonocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyQuality of visionOptometrySurgeryFemalesense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct