0000000000711089

AUTHOR

Nick Tovar

Microtomographic reconstruction of mandibular defects treated with xenografts and collagen-based membranes:a pre-clinical minipig model

Background The goal of this study was to evaluate hard tissue response following guided bone regeneration using commercially available bovine bone grafts and collagen membranes; bilayer collagen membrane and porcine pericardium-based membrane, by means of a non-destructive three-dimensional (3D) computerized volumetric analysis following microtomography reconstruction. Material and Methods Bone regenerative properties of various bovine bone graft materials were evaluated in the Göttingen minipig model. Two standardized intraosseous defects (15mm x 8mm x 8mm) were created bilaterally of the mandible of eighteen animals (n=72 defects). Groups were nested within the same subject and randomly d…

research product

Effect of implant placement depth on the peri-implant bone defect configurations in ligature-induced peri-implantitis : an experimental study in dogs

Background The subcrestal placement of implant platform has been considered a key factor in the preservation of crestal bone, but the influence of implant placement depth on bone remodeling combined with peri-implantitis is not fully understood. The aim of this study was to assess the effect of the crestal or subcrestal placement of implants on peri-implant bone defects of ligature-induced peri-implantitis in dogs. Material and Methods Eight weeks after tooth extraction in six beagle dogs, two different types of implants (A: OsseoSpeed™, Astra, Mölndal, Sweden; B: Integra-CP™, Bicon, Boston, USA) were placed at either crestal or subcrestal (-1.5 mm) positions on one side of the mandible. Li…

research product

Assessing osseointegration of metallic implants with boronized surface treatment

Background Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. Material and Methods Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined …

research product

Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in sheep.

Background This study aimed to compare the histomorphometric and histological bone response to laser-sintered implants followed by resorbable-blasting media (RBM) process relative to standard machined/RBM surface treated implants. Material and Methods Six male sheep (n=6) received 2 Ti-6Al-4V implants (1 per surface) in each side of the mandible for 6 weeks in vivo. The histomorphometric parameters bone-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated. Results Optical interferometry revealed higher Sa and Sq values for the laser-sintered/RBM surface in relation to standard/RBM implants. No significant differences in BIC were observed between the two groups (p>0.2…

research product

Osteogenic parameters surrounding trabecular tantalum metal implants in osteotomies prepared via osseodensification drilling

Background Surgical fixation of implants into bone for the correction of bone deformities or defects is a traditional approach for skeletal stabilization. Important measures of efficacy of implants include implant stability and osseointegration—the direct interaction between living bone and an implant. Osseointegration depends on successful implant placement and subsequent bone remodeling. This study utilized osseodensification drilling (OD) in a low bone density model using trabecular metal (TM) implants. Material and Methods Three osteotomy sites, Regular, OD-CW (clockwise), and OD-CCW (counterclockwise), were prepared in each ilium of three female sheep. Drilling was performed at 1100rpm…

research product