0000000000719102

AUTHOR

M. Kostrzewa

Confinement-induced polymorphism in acetylsalicylic acid–nanoporous glass composites

We report on the experimental observation of confinement-induced new phase appearance in acetylsalicylic acid (ASA)–porous glass (PG) composites. In this study, ASA was embedded in PG host matrices of various pore widths (15–200 nm). The Raman spectra and positron annihilation lifetime measurements exhibit the existence of ASA nanocrystals in the PG matrix. The DSC data revealed that the melting temperature TM and excess specific heat decrease with decreasing the size of embedded ASA nanocrystals. The close inspection of the TM dependence versus diameter of filled pores has shown that the ASA crystallizes in polymorph II in confined matrix. Moreover, it was demonstrated that the ASA spatial…

research product

Positron Annihilation with Electrons of Admixture Atoms in Some Binary Nickel Alloys

Weighted difference curves have been shortly presented as a proper tool allowing to analyze in another way two-detector Doppler spectra regarding positron annihilation with admixture electrons in some nickel alloys. The analysis of low and middle momentum parts of Doppler spectra for investigated alloys reflects the annihilation of positrons with admixture electrons. There is no distinct signal of annihilations with admixture electrons from the positron lifetime data for well-annealed samples.

research product

A two-detector spectrometer for measurements of Doppler broadened positron annihilation spectra

Abstract A two-detector spectrometer for measurements of Doppler broadened positron annihilation spectra has been constructed and tested. The energy difference of the annihilation quanta is measured in the analogue, not in the digital manner. The peak to background ratio in the measured spectra is of the order of 10 6 , the FWHM representing the energy resolution, equals to 1.1 keV , thus enabling the very subtle physical effects to be revealed. Some information on electronic structure of the investigated 3-d metals (Ti, V, Cr, Fe, Ni, Cu and Zn) has been determined using this spectrometer. It has been shown that the apparatus permits to detect the impurity-vacancy pairs in dilute nickel al…

research product

Positron Lifetime in Hostaphan

Positron lifetime measurements in hostaphan RNK, used for encapsulation of Na positron sources, were performed. It was found that the parameter of positron lifetime spectra in hostaphan RNK differ markedly from those for other forms of polyethylene terephthalate. The maximum penetration depth of positrons from RNK hostaphan amounts 0.42 mm. The information gained in the present study is of great importance for experimenters using hostaphan RNK for encapsulation of positron sources.

research product

Test Measurements of Modernized Version of Two-Detector Doppler Spectrometer

The quality of the annihilation quanta energy measurements (Doppler effect) has greatly increased when experimenters have begun to introduce Doppler apparatus modifications. In the basic version, the experimental set-up consisted of high energy resolution Ge(Li) detector, amplifier and multichannel analyser. A simple construction and short time of data acquisition were the main advantages of that version of the apparatus. Competitive, angular correlation of annihilation radiation (ACAR) method was better from the resolution point of view and not worse when considering the range of momentum distribution, but the ACAR method required high activity positron sources and data acquisition time wa…

research product

Studying of Nickel Alloys with 1 at.% of Ge, Zn, In, Zr and Pb by Positron Annihilation Methods

research product